Zone ON definition depends on the Normally Open/Normally Closed
setting of the Zone Type, i.e. Closed contact for N.O zones and open
contacts for N.C zones.
(( The Zone Response is activated even if the zone is Inactive
(e.g. in Security Off), and before any Alarm Response triggered
by the zone.
Zone Off Response (1,6)
System says the current OFF response when this zone is deactivated
and asks for a new response number and # key. The OFF response is
executed whenever this zone is deactivated. A response can perform
home automation actions, or arm and disarm the security system etc...
Enter 0 if no OFF response is required. e.g.
OFF Response 16,
Enter new number and # key
Enter new response and #, or # to leave the response unchanged.
Refer to the Default Responses list
Zone OFF definition depends on the Normally Open/Normally Closed
setting of the Zone Type, i.e. Closed contact for N.C zones and open
contacts for N.O zones.
(( The Zone Off Response is activated even if the zone is Inactive,
e.g. in Security Off Mode