User manual
Table Of Contents
- Important Safety Instructions 2
- 1.0 Primary Checks
- 2.0 Installation
- 3.0 Warranty Information
- 4.0 Introduction
- 5.0 Features
- b: DATA Indicator
- a: Power Indicator
- c: IQ Interface Indicator
- d: Input Gate Status Display
- e: Digital Display
- f: Selector Buttons
- g: RECALL Button
- h: IR Sensor
- i: RS232 connector
- 7.0 Rear panel
- A: Audio Inputs
- B: Audio Outputs
- C: CobraNet® Connectors
- E: RS232 Serial Port
- D: IQ Loop Connectors
- F: Control Port
- G: Mains Power Inlet
- Using the PS-8810
- 8.0 Quick Install Procedure
- Hardware Installation & Connections
- Connecting to a Host Computer
- RS232 Computer Connection
- Set the Baud Rate
- Comms Problems
- Connecting the IQ Loop
- Set the IQ Address
- PS-8810 as a single loop IQ Interface
- PS-8810 in an IQ Loop system
- IQ Component Connections
- IQ Loop Wiring
- Audio Wiring
- About the Audio Inputs
- Suggested Audio Input Gain Control Settings
- Balanced Input Wiring
- Unbalanced Input Wiring
- About the Audio Outputs
- Balanced Output Wiring
- Unbalanced Output Wiring
- CobraNet® Connections
- Control Port Connections
- Modem Connection
- PC Requirements
- System Overview
- Presets and Scenes
- IQ Win Overview
- Processing Functions
- Output Level Meters
- Output Dynamic Cut/Boost Meters
- Input Level Meters
- Input Dynamic Cut/Boost Meters
- Preset Information
- Status Window
- CPU Utilisation
- DSP
- General
- Real Time Clock
- Front Panel Control Lock Out
- Data
- Interface
- LED Display Mode
- Front Panel Access
- User Labels
- Firmware Information
- Signal Path
- Input Selector
- Input Meter
- Input Select Switch
- Input Processing Selection
- Input Signal Fader, Muter, and Inverter
- Output Overview
- Inputs Window Link
- Input/Output Matrix Link
- Input Filters
- Type
- Frequency
- Gain
- Band EQ
- Shape
- Post-Processing Filters
- Input Delay
- Hardware Delays
- Input Gate
- Enable Gate
- Depth
- Static Threshold
- Hysteresis
- Signal Delay
- Attack Time
- Hold Time
- Release Time
- Side-chain Filter
- Auto-Leveler
- On/Off
- Target Level
- Max Gain
- Idle Gain
- Open to...
- Threshold
- Attack Time
- Release Time
- Input Compressor
- On/Off
- Compression Ratio
- Threshold
- Soft Knee (Width)
- Attack Time
- Release Time
- Side-chain Filter
- Priority Ducking
- Automixer
- Automixing Group Controls
- Priority Mix Enable
- Max Number of Open Mics
- Highest Open Mic Priority Indicator
- Total Number of Open Mics Indicator
- NOM Attenuation
- Adaptive Gating
- Enable
- Mode
- Step Size
- Enable
- Ambient Level Meter
- Group Gate Threshold Ambient Offset
- Ambience Weighting
- Automix Matrix
- Automixing Individual Controls
- Priority
- Depth of Cut
- Attack Time
- Release Time
- Solo/Mute
- Input/Output Matrix
- Output Path
- Output Section
- Output Delay
- Output Filters
- Ambient Leveler
- On/Off
- Sense Input
- Sense Threshold
- Program Level Dependent Mode
- Expansion Ratio
- Max Added Gain
- Attack Time
- Release Time
- Program Level Threshold
- Sense Delay
- Output Limiter
- On/Off
- Threshold
- Attack Time
- Release Time
- Output Select
- 12.0 Presets
- Preset Segue
- Scenes
- Scene Editor
- Events Scheduler
- One Time Events
- Periodic Events
- Schedule
- Explanation
- 15.0 CobraNet®
- Setup
- System Name
- System Description
- System Location
- System Contact
- Firmware Version
- MAC Address
- IP Address
- Conductor
- Status indicators
- Input
- Output
- External Control
- 16.0 Infrared Remote Control
- IR Code Editor
- Infrared Remote Control
- PS8810 IR Code Format
- 17.0 Control Port
- Digital Inputs
- Set Object(s)
- Room Combine
- Bump Object(s)
- Bump Object(s) Continuously
- Recall Preset
- Recall Scene
- Digital Outputs
- Analogue Inputs (AIN 1-8)
- Analogue Outputs
- Reference Section
- 18.0 Technical Information
- Audio
- Input Section
- DSP Processing Section
- Output Section
- 19.0 Block Diagram
- 20.0 Specifications
- 21.0 User Notes
- Untitled

- 18 -
PS-8810
DIGITAL SIGNAL PROCESSOR
When a parameter is changed, a small indicator (A) momentarily
lights to show the parameter has been stored in FLASH memory.
Another small indicator (B) is illuminated whenever any
parameter is varied from its value within the currently selected
Preset.
Front panel control may be 'locked out' via IQ for Windows
software. The display reads “Lxx” rather than the usual “Pxx” to
indicate the locked status of the controls.
Two front panel buttons are provided to switch between 'Presets',
select 'Scenes', change 'IQ address', and choose RS232 baud
rate.
The RECALL button, when pressed and held for longer than 2
seconds, causes the display to cycle through the available
choices until it is released; first to 'Scene select' mode, then
'Address select' mode, 'Baud rate select' mode, and finally back
to 'Preset select' mode. For more information about these
features please refer to the Hardware Installation & Connections
section - chapter 9.0.
Once the RECALL button is released, the PRESET UP and DOWN
arrow buttons are used to adjust the parameter. On releasing the
RECALL button, the user has two seconds to begin using the UP
or DOWN arrow buttons before the display changes back to
default. When the parameter is adjusted to the desired value,
press the RECALL button again to store the setting.
Infra Red (IR) sensor for use with remote control systems such as
Philips Pronto. Do not cover! The power indicator will flash
when IR commands are received.
Serial port connector for connection to computer using RS232
protocol.
Front Panel
f: Selector Buttons
A
B
g: RECALL Button
Selector Buttons and Digital Display
h: IR Sensor
i: RS232 connector