User manual

Table Of Contents
- 110 -
PS-8810
DIGITAL SIGNAL PROCESSOR
Control Port Analogue Outputs
Analogue Outputs
In addition to the eight Digital Outputs, there are eight Analogue
Outputs that can be used to provide an output voltage (0 to
+10VDC for control). These outputs can reflect a particular
analogue object such as a fader, or a switched object and, can be
used to provide drive for such things as lighting controls or for a
standard digital type output.
The settings are remembered in a Preset, so they can be used to
change the voltage of a particular output based upon Preset.
There is one indicator and six controls for each output.
Pin State Indicator: indicates the logical 'Pin-High' or 'Pin-
Low' status of the actual hardware output
Manual: directly controls the binary output state of the
corresponding pin when in Manual mode
Polarity: changes the polarity of the analogue output
regardless of the pin control mode
Reflect Manual: causes the output to directly reflect the state
of its Manual control
Reflect Binary: causes the digital output to reflect the state of
the selected binary object within the BSS PS-8810. Only a
single object may be specified
Reflect Slider: causes the analogue output to reflect the
setting of the slider control associated with the output
Reflect db: causes the analogue output to reflect the status of
the selected db object. Only a single db object may be
specified.