User manual

Table Of Contents
- 107 -
PS-8810
DIGITAL SIGNAL PROCESSOR
Control Port Digital Outputs
Digital Outputs
There are eight digital outputs. Each output may be controlled
manually, configured to indicate the state of a binary object or,
configured to indicate whether a particular Preset is loaded. There
is one indicator and five controls for each output:
Pin State Indicator: indicates the logical ‘Pin-High’ or ‘Pin-
Low’ status of the actual hardware output
Manual: directly controls the output state of the
corresponding pin when in Manual mode
Polarity: changes the polarity of the digital output regardless
of the pin control mode
Reflect Manual: causes the output to directly reflect the state
of its Manual control
Reflect Object: causes the output to reflect the state of the
selected binary object within the BSS PS-8810. Only a single
object may be specified.
Reflect Preset: causes the output to reflect whether the
chosen Preset number is loaded within the BSS PS-8810
When the Control Port digital outputs are turned 'on', +10VDC at
10 mA is supplied across the output to ground. A total of 1 amp of
current is available.