Soundweb TM SoundwebTM 9014 Installation Guide 122
v1.0 MR/JMK 8th September 1999 An example of this equipment has been tested and found to comply with the following European and international Standards for Electromagnetic Compatibility (only when used with a metal wallbox). Radiated Emissions (EU): EN55022 (1995) Associated Equip.
Soundweb TM Use The 9014 requires 12-24v DC to be supplied externally. There are two ways of getting power into the unit: • Connect a 24v 1A DC power supply to the 2.4mm barrel connector. Up to nine more 9014s may be powered from the paralleled combicon connector. • Connect a 12-24v DC power supply to the combicon connector. A pair of 9014 Fibre Interface units are used to replace a standard category 5 Soundweb network cable. Each fibre cable will transfer 8 channels of digital audio plus control data.
The unit has three LED indicators showing: Power Steady - This indicates the power supply is functioning. Fibre-in Steady – Data is arriving on the fibre input. Intermittent – You have exceeded the optical power budget by either exceeding the maximum fibre length or by having too much attenuation in fibre splices. See the specification section. Cable-in Steady – Data is arriving on the cable.
Soundweb TM Technical specifications Power DC Supply 12-24V DC, <5VA Connector Phoenix screw terminal or 2.4mm inline barrel connector Network Single RJ-45 Auto-sensed input node or output node - no setup required. Max cable length 20m Fibre Connection Snap-in SC fibre input Snap-in SC fibre output Fibre cable Multimode 62.5/125um or Multimode 50/125um Optical Power Budget 10dB Max fibre length 2000 metres/6550 feet/1.2 miles N.