Instruction Manual

9
|
www.bs-battery.com
8
CHARGING TEST (ALTERNATOR TEST)
Tester prompts as following:
Charging
Test
Increasing
RPM to 2500r/
min, keep it 5s.
Press ENTER
to continue.
Charging
Test
Charging Test
Loaded
Testing
****
Testing
****
Loaded 14.16V
Unloaded 14.39V
Replace 15mV
Charging Normal
Charging Test
1. Charging Test result: Normal
Charging system shows the generator output normal, no problem detected.
2. Charging Test result: Low
Charging volt of the charging system is low.
Check drive belt of the generator whether slip or running off.
Check the connection between generator and battery is normal or not.
If both of the drive belt and the connection are in good condition, follow the manufacturer’s
suggestion to eliminate generator fault.
3. Charging test result: High
Generator output volt is high. Since most of the vehicle generators are using internal
regulator, the generator assembly has to be replaced.(Some old style cars are using
external regulator, then directly replace the regulator.).
The normal high volt of the voltage regulator is maximum 14.7±0.5V. If charging volt is
too high, it will overcharge the battery. Therefore the battery life will be shortened and
troubles will be caused.
4. No Volt Output:
No generator volt output is detected. Check the generator connection cable and the belt
whether they are normal.
5. Diode Test:
Through the test of charging current ripple, tester will nd out whether the diode is normal
or not. When ripple volt is too high, it proves at least one diode is damaged. Check and
replace the diode.
REVIEW DATA
Choose the function of Review Data and review the history of battery testing result.
Health:96% 490CCA
Charge:98% 12.64V
Internal R=6.1mΩ
Rated: 500A
GOOD BATTERY
PRINT DATA
Choose the function of Print and press ENTER.
Before choose the print data function, it is necessary to connect the battery tester to the
computer via USB cable.
Once all are available, please install the print program on your computer.
1. Install the USB driver rstly.
DRIVER HERE
2. Then open the Print software.
3. Click OPEN PORT in the Print software and choose the COM NO.
If there are some data history in print software, please kindly clear them.
4. The Printer of computer will print the testing result via PC.
PRODUCT SETUP
The tool allows you to make the following adjustments and settings:
Language: selects desired language.
Contrast adjustment: adjusts the contrast of the LCD display.
Tool information: the tool show the version.
To enter the system setup menu: from main menu, select the System Setup and press
ENTER.
System Setup
Language
Contrast
Tool Information