Operating instructions

12/23/2011 12 EI711A
Field Setup or Programming
Evolution/Infinity stat setup menu – it is extremely important and required that the roomstat setup
menu be reprogrammed as shown below. This list highlights the items which are important for WarmFlo
Select combination and is not the complete setup menu.
THERMOSTAT SETUP
MAXIMUM CYCLES PER
HOUR: 4
ANTICIPATOR: 3
BACK
10 kW, 3-ton or smaller.
FURNACE SETUP
FURNACE
AIRFLOW: COMFORT
AC AIRFLOW: COMFORT
DEHUM AIRFLOW: NORMAL
LOW HEAT RISE: ON
STAGING: SYSTEM
HIGH STAGE
TIMER: 10 MIN.
BACK NEXT
AIRFLOW: COMFORT
AC airflow: COMFORT
DEHUM airflow: NORMAL (default).
15-25 kW, 3-ton or larger.
FURNACE SETUP
FURNACE
AIRFLOW: EFFICIENCY
AC AIRFLOW: EFFICIENCY
DEHUM AIRFLOW: NORMAL
LOW HEAT RISE: ON
STAGING: SYSTEM
HIGH STAGE
TIMER: 10 MIN.
BACK NEXT
AIRFLOW: EFFICIENCY
AC airflow: EFFICIENCY
DEHUM airflow: NORMAL (default).