Instruction manual

14
Remove relief tube from relief
port on collector trap.
Remove trap from
collector box.
Loosen clamp on inlet
to vent elbow.
Remove pressure switch tube from
front pressure switch and discard.
Remove tube from relief port.
Remove middle and bottom
plugs. DO NOT DISCARD.
Install plugs in
open ports on
collector box.
Connect relief tube
to port on collector
box.
Rotate elbow to
desired position and
tighten clamp to
15 lb.-in.
Slide tube in stand-offs
to adjust length.
Connect tube from Loose Parts bag
to port on front pressure switch.
Route tube through inducer
stand-offs.
Trim excess tube.
Connect pressure switch
tube to port on collector
box.
Attach condensate trap
with screw to collector box.
Connect relief tube to
relief port on condensate
trap.
Align condensate trap
over middle and bottom
ports of collector box.
4
5
Downflow Trap Configuration
Unconverted Factory Configuration
As Viewed in the Downflow Orientation
A11280
Fig. 9 -- Downflow Trap Configuration
986TA