Instruction manual

1
986TA
TWO--STAGE VARIABLE--SPEED ECM
MULTIPOISE GAS FURNACE
SERIES 100/A
Installation, Start--up, Operating and
Service and Maintenance Instructions
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS 3.........................
INTRODUCTION 4...................................
CODES AND STANDARDS 4...........................
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS 4...
ACCESSORIES 5.....................................
LOCATION 5........................................
AIR FOR COMBUSTION AND VENTILATION 9..........
CONDENSATE TRAP 12...............................
Upflow 12........................................
Downflow 12.....................................
Horizontal 12......................................
CONDENSATE DRAIN 17.............................
INSTALLATION 19...................................
Upflow 19........................................
Downflow 19.....................................
Horizontal 20......................................
Filter Arrangement 21...............................
AIR DUCTS 27.......................................
Ductwork Acoustical Treatment 27.....................
GAS PIPING 30......................................
ELECTRICAL CONNECTIONS 31.......................
115--V Wiring 31...................................
J--Box Installation 32................................
24--V Wiring 32....................................
Accessories 32.....................................
Alternate Power Supplies 33..........................
VENTING 39........................................
Special Venting Requirements for Installations in Canada 39.
Materials 40.......................................
Venting Systems 40.................................
Locating Vent Termination 40.........................
Size the Vent and Combustion Air Pipes 41...............
Combustion Air and Vent Piping Insulation Guidelines 41...
Configure the Furnace 42............................
Installing the Vent Termination 43......................
Venting System Length Calculations 46.................
START--UP, ADJUSTMENT, AND SAFETY CHECK 59......
Select Setup Switch Positions 59........................
Prime Condensate Trap 59.............................
Purge Gas Lines 59...................................
Adjustments 60......................................
Check Safety Controls 62..............................
Checklist 62........................................
SERVICE AND MAINTENANCE PROCEDURES 69........
Cleaning Heat Exchangers 74...........................
SEQUENCE OF OPERATION 77........................
PARTS REPLACEMENT GUIDE 84......................
TABLES
Loose Parts Bag Contents 6..............................
Minimum Clearances to Combustible Materials 6.............
Minimum Free Area Required 11.........................
Minimum Space Volumes 11.............................
Filter Size Information 21...............................
Opening Dimensions 23................................
Air Delivery CFM 28...................................
Maximum Capacity of Pipe 31...........................
Electrical Data 34......................................
Vent Termination Kit for Direct Vent (2--Pipe) Systems 40......
Combustion--Air Vent Pipe, Fitting & Cement Material.. 44.....
Maximum Allowable Exposed Vent Lengths Insulation 45......
Maximum Equivalent Vent Length 46......................
Deductions from Maximum Equivalent Vent Length 46........
Altitude Derate Multiplier for U.S.A. 66....................
Blower Off Delay Setup Switch 66........................
Gas Rate 66..........................................
Orifice Size and Manifold Pressure 67.....................
CERTIFIED
Always Ask For
Use of the AHRI Certified
TM
Mark indicates a
manufacturers participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
Portions of the text and tables are reprinted from NFPA 54/ANSI
Z223.1--2009E, with permission of National Fire Protection
Association, Quincy, MA 02269 and American Gas Association,
Washington DC 20001. This reprinted material is not the complete
and official position of the NFPA or ANSI on the referenced
subject, which is represented only by the standard in its entirety.

Summary of content (84 pages)