Instruction manual
12
For Horizontal Left only:
S Connect the relief tube to the relief port of the condensate trap.
S Connect the pressure switch tube to the port on the collector box
next to the condensate trap. Trim off any excess tube to avoid
sags or kinks in the tube.
S Rotate the vent elbow to the desired position and tighten the
clamp 15 lb--in.
S Refer to Condensate Drain section for information how to install
the condensate drain.
Condensate Drain Protection
Freezing condensate left in condensate trap and drain line may
cause cracks, and possible water damage may occur. Freeze
protection of the condensate trap is required when the furnace is
installed in the horizontal position and the attic temperature is
below 32 deg. F (0 deg. C).
If freeze protection for the condensate trap is required, use
condensate freeze protection accessory.
See Product Data for current kit offering.
The remaining condensate drain line can be protected by using a 3
to 6 watt per ft. (.3M) at 120v and 40_F(4.4_C) self--regulating,
shielded, and waterproof heat tape. Wrap field drain pipe with heat
tape, approximately 1 wrap per ft. (.3M). Follow manufacturer’s
recommendations and installation instructions supplied with heat
tape.
Condensate Trap
Relief Port
Collector Box
Plugs
Pressure Switch
Port
Condensate Trap
Outlet
Condensate Trap
Relief Port
Collector Box
Plug
Vent Elbow
Vent Elbow Clamp
Vent Pipe Clamp
A11306
Fig. 7 -- Upflow Trap Configuration
(Appearance May Vary)
987MA