Specifications

TYPICAL WIRING SCHEMATIC 619E HIGH WALL UNITS
THERMISTOR EQUIVALENCE
TEMPERATURE RESISTANCE
°F °C V
95 35 6,500
72 22 11,400
32 0 32,500
ALL THERMISTORS IN THE SYSTEMS USING
619E UNITS ARE IDENTICAL TO EACH OTHER
NOTES:
1. If any of the original wire furnished must be replaced, it must be replaced
with type 90 C wire or its equivalent.
2. Wire in accordance with National Electrical Code (NEC) and local codes.
3. A thermistor wiring cable is provided with the fan coil unit.
4. Fan motor has internal thermal protection.
5. Transformer has an internal 2 amp thermal fuse on the primary side.
LEGEND
AGING For Burn-In Test
(short terminals)
AS Assembly
C—Contactor
CN Connector
COMP Compressor
EMI Electromagnetic
Interference
FMC Fan Motor Capacitor
G, GND Ground
HA Home Automation
HS Hall-Effect Sensor
IDC Th Indoor-Coil Thermistor
IDFM Indoor-Fan Motor
JEM-A Japan Electric
Manufacturing
Industry Association
L—Left
PCB Printed Circuit Board
R—Right
RA Th Return-Air Thermistor
RC Resistor Capacitor
RCV Receiver
TB Terminal Block
TP Thermal Protector
TRAN Transformer
Terminal (Marked)
Terminal (Unmarked)
Splice
Terminal Block
Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or
Optional Wiring
45