Product data

GROSS COOLING CAPACITIES (cont)
SYSTEM 4* HIGH WALL SYSTEM; 538A024 WITH 619E024
TEMP (F)
AIR ENTERING
CONDENSER
(Edb)
AIR ENTERING EVAPORATOR CFM/BF
456/0.04 502/0.04 550/0.05
Air Entering Evaporator Ewb (F)
57 62 67 72 57 62 67 72 57 62 67 72
55
TCG 20.9 22.2 23.1 23.6 21.4 22.6 23.5 23.9 21.8 22.4 23.4 23.7
SHG 20.3 17.6 14.5 11.5 21.2 18.3 15.0 11.7 21.8 18.6 15.1 11.7
TC 20.7 22.0 22.9 23.4 21.1 22.4 23.3 23.6 21.5 22.2 23.2 23.5
kW 1.34 1.34 1.35 1.35 1.34 1.35 1.36 1.36 1.35 1.35 1.36 1.36
CMP 1.16 1.16 1.17 1.17 1.16 1.17 1.17 1.17 1.16 1.16 1.17 1.17
LDB 39.0 44.5 50.9 57.1 41.3 46.5 52.7 58.8 43.7 49.1 54.8 60.6
LWB 37.5 43.3 49.7 56.4 39.1 45.0 51.2 57.9 40.6 46.8 52.9 59.4
65
TCG 20.4 22.1 23.4 24.1 21.0 22.5 23.7 24.5 21.6 22.9 23.8 24.8
SHG 20.1 17.7 14.8 11.7 21.0 18.5 15.2 12.0 21.6 19.3 15.6 12.2
TC 20.2 21.9 23.2 23.9 20.8 22.3 23.5 24.2 21.4 22.6 23.6 24.5
kW 1.48 1.49 1.50 1.50 1.49 1.50 1.50 1.51 1.50 1.51 1.51 1.52
CMP 1.30 1.31 1.32 1.32 1.30 1.31 1.32 1.32 1.31 1.31 1.32 1.33
LDB 39.4 44.3 50.3 56.6 41.5 46.1 52.3 58.3 43.9 47.9 54.1 59.8
LWB 38.0 43.4 49.4 56.0 39.4 45.0 51.1 57.5 40.7 46.5 52.6 58.8
75
TCG 19.8 21.5 23.2 24.7 20.5 22.0 23.5 24.6 21.2 22.4 23.8 24.9
SHG 19.7 17.5 14.8 12.0 20.5 18.4 15.2 12.1 21.2 19.2 15.8 12.4
TC 19.6 21.3 23.0 24.5 20.3 21.8 23.2 24.4 21.0 22.2 23.6 24.7
kW 1.64 1.66 1.66 1.68 1.66 1.67 1.67 1.68 1.67 1.67 1.68 1.69
CMP 1.46 1.48 1.48 1.50 1.47 1.48 1.48 1.49 1.47 1.48 1.49 1.50
LDB 40.2 44.8 50.3 56.1 42.4 46.4 52.3 58.1 44.6 48.0 53.8 59.5
LWB 38.7 44.0 49.6 55.6 39.9 45.5 51.3 57.4 41.0 46.8 52.6 58.7
85
TCG 19.2 20.8 22.7 24.3 19.9 21.3 23.1 24.4 20.6 21.7 23.5 24.8
SHG 19.2 17.1 14.6 11.8 19.9 18.1 15.1 12.0 20.6 19.0 15.7 12.4
TC 19.0 20.6 22.5 24.1 19.7 21.1 22.9 24.2 20.4 21.5 23.2 24.5
kW 1.82 1.84 1.85 1.87 1.84 1.85 1.86 1.87 1.85 1.87 1.87 1.88
CMP 1.65 1.66 1.67 1.69 1.65 1.67 1.68 1.69 1.66 1.67 1.68 1.69
LDB 41.3 45.5 50.7 56.4 43.5 47.0 52.4 58.2 45.6 48.4 53.8 59.5
LWB 39.3 44.7 50.1 55.9 40.5 46.1 51.6 57.5 41.5 47.4 52.9 58.8
95
TCG 18.6 20.0 22.0 23.9 19.4 20.5 22.4 24.2 20.0 20.9 22.8 24.4
SHG 18.6 16.8 14.3 11.7 19.4 17.7 14.9 12.0 20.0 18.6 15.6 12.3
TC 18.4 19.8 21.8 23.7 19.1 20.3 22.2 24.0 19.8 20.7 22.6 24.1
kW 2.03 2.05 2.07 2.09 2.05 2.06 2.08 2.10 2.06 2.07 2.09 2.10
CMP 1.85 1.87 1.89 1.91 1.86 1.88 1.89 1.91 1.87 1.88 1.90 1.91
LDB 42.5 46.3 51.3 56.7 44.6 47.7 52.8 58.2 46.6 49.1 54.1 59.7
LWB 39.9 45.5 50.7 56.2 41.1 46.8 52.1 57.7 42.1 48.0 53.3 59.0
105
TCG 18.1 19.3 21.2 23.1 18.8 19.7 21.7 23.5 19.4 20.1 22.1 23.7
SHG 18.1 16.4 14.0 11.4 18.8 17.3 14.6 11.7 19.4 18.2 15.3 12.0
TC 17.9 19.1 21.0 22.9 18.5 19.5 21.5 23.3 19.1 19.9 21.9 23.5
kW 2.26 2.28 2.31 2.33 2.28 2.30 2.33 2.34 2.30 2.31 2.34 2.35
CMP 2.08 2.10 2.13 2.15 2.10 2.11 2.14 2.16 2.11 2.12 2.15 2.16
LDB 43.6 47.0 51.9 57.3 45.7 48.4 53.3 58.7 47.7 49.7 54.6 60.1
LWB 40.5 46.2 51.3 56.8 41.6 47.5 52.6 58.2 42.6 48.6 53.8 59.4
115
TCG 17.5 18.5 20.4 22.4 18.1 19.0 20.9 22.7 18.7 19.3 21.2 23.0
SHG 17.5 16.0 13.6 11.1 18.1 16.9 14.3 11.4 18.7 17.8 14.9 11.8
TC 17.3 18.3 20.2 22.2 17.9 18.7 20.6 22.5 18.5 19.1 21.0 22.8
kW 2.53 2.55 2.59 2.61 2.55 2.56 2.60 2.62 2.57 2.58 2.62 2.63
CMP 2.35 2.37 2.41 2.43 2.36 2.38 2.42 2.44 2.38 2.39 2.43 2.44
LDB 44.8 47.7 52.7 57.8 46.8 49.1 54.0 59.2 48.8 50.4 55.2 60.5
LWB 41.2 46.9 52.0 57.4 42.2 48.1 53.3 58.7 43.2 49.2 54.4 59.9
125
TCG 16.9 17.8 19.6 21.6 17.5 18.2 20.0 21.9 18.1 18.5 20.4 22.2
SHG 16.9 15.7 13.3 10.8 17.5 16.5 13.9 11.2 18.1 17.4 14.6 11.5
TC 16.7 17.6 19.4 21.4 17.3 17.9 19.8 21.7 17.9 18.3 20.1 22.0
kW 2.83 2.85 2.90 2.93 2.85 2.87 2.91 2.94 2.87 2.88 2.93 2.95
CMP 2.65 2.67 2.72 2.75 2.67 2.68 2.73 2.76 2.68 2.69 2.74 2.76
LDB 46.0 48.5 53.4 58.5 48.0 49.8 54.7 59.8 49.8 51.0 55.8 61.0
LWB 41.8 47.6 52.8 58.0 42.8 48.8 53.9 59.3 43.7 49.8 55.0 60.4
Rating condition.
Not recommended for long-term operation.
LEGEND
BF Bypass Factor
CMP Compressor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Total Power
LDB Leaving Dry Bulb
LWB Leaving Wet Bulb
SHG Gross Sensible Capacity (1000 Btuh)
TC Total Net Cooling Capacity (1000 Btuh)
TCG Gross Cooling Capacity (1000 Btuh)
*Refer to Systems Index Table on page 21.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The SHG is based on 80 F edb temperature of air entering indoor
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHG.
Above 80 F edb, add (corr factor x cfm) to SHG.
Correction Factor = 1.10 x (1 BF) x (edb 80).
25