Product data

GROSS COOLING CAPACITIES
SYSTEM 1* HIGH WALL SYSTEM; 538C009 WITH 619E009
TEMP (F)
AIR ENTERING
CONDENSER
(Edb)
AIR ENTERING EVAPORATOR CFM/BF
184/0.08 200/0.09 215/0.10
Air Entering Evaporator Ewb (F)
57 62 67 72 57 62 67 72 57 62 67 72
55
TCG 7.41 7.46 7.72 7.87 7.41 7.44 7.61 7.76 7.45 7.71 7.52 7.66
SHG 7.10 5.75 4.78 3.88 7.18 5.79 4.74 3.85 7.30 6.09 4.70 3.82
TC 7.33 7.38 7.65 7.80 7.33 7.36 7.53 7.68 7.37 7.63 7.43 7.57
kW 0.597 0.597 0.608 0.613 0.598 0.598 0.605 0.611 0.601 0.611 0.603 0.609
CMP 0.493 0.494 0.505 0.511 0.493 0.493 0.500 0.507 0.494 0.505 0.496 0.503
LDB 43.5 50.5 55.5 60.2 46.1 52.7 57.7 62.0 47.9 53.3 59.5 63.4
LWB 39.6 46.4 52.7 59.1 41.3 47.9 54.2 60.5 42.4 48.5 55.4 61.6
65
TCG 7.48 7.80 8.17 8.46 7.60 7.79 8.18 8.34 7.67 8.06 8.09 8.24
SHG 7.29 6.14 5.10 4.13 7.52 6.20 5.15 4.10 7.65 6.53 5.12 4.07
TC 7.40 7.73 8.10 8.38 7.53 7.71 8.10 8.26 7.59 7.97 8.00 8.16
kW 0.649 0.661 0.677 0.690 0.656 0.662 0.679 0.686 0.660 0.677 0.677 0.683
CMP 0.547 0.559 0.574 0.587 0.552 0.558 0.574 0.581 0.554 0.570 0.570 0.576
LDB 42.5 48.5 53.9 58.9 44.4 50.8 55.8 60.8 46.4 51.3 57.6 62.3
LWB 39.4 45.6 51.7 58.0 40.8 47.1 53.1 59.5 41.9 47.8 54.4 60.7
75
TCG 7.54 7.94 8.46 8.58 7.73 8.05 8.48 8.56 7.90 8.12 8.49 8.82
SHG 7.48 6.37 5.34 4.18 7.73 6.57 5.41 4.20 7.90 6.73 5.47 4.34
TC 7.47 7.87 8.38 8.50 7.65 7.97 8.40 8.48 7.81 8.04 8.40 8.73
kW 0.715 0.728 0.749 0.753 0.724 0.734 0.752 0.754 0.733 0.738 0.754 0.770
CMP 0.613 0.625 0.647 0.651 0.619 0.629 0.647 0.650 0.626 0.631 0.648 0.663
LDB 41.5 47.3 52.7 58.7 43.5 49.0 54.5 60.3 45.3 50.5 56.1 61.1
LWB 39.3 45.2 51.0 57.8 40.5 46.5 52.5 59.1 41.4 47.7 53.6 59.7
85
TCG 7.44 7.90 8.40 8.87 7.67 8.05 8.50 8.91 7.80 8.16 8.56 9.17
SHG 7.44 6.45 5.36 4.31 7.67 6.70 5.50 4.37 7.80 6.93 5.61 4.53
TC 7.37 7.83 8.33 8.79 7.59 7.97 8.42 8.83 7.72 8.07 8.48 9.08
kW 0.790 0.801 0.816 0.837 0.803 0.810 0.822 0.841 0.801 0.817 0.826 0.859
CMP 0.688 0.698 0.713 0.735 0.699 0.704 0.717 0.737 0.695 0.710 0.720 0.752
LDB 41.7 46.9 52.5 58.0 43.7 48.4 54.1 59.5 45.7 49.6 55.4 60.3
LWB 39.5 45.3 51.2 57.2 40.6 46.6 52.4 58.5 41.6 47.6 53.5 59.2
95
TCG 6.92 7.51 8.33 8.85 7.16 7.82 8.47 8.95 7.47 7.95 8.59 9.14
SHG 6.92 6.29 5.38 4.32 7.16 6.64 5.57 4.41 7.47 6.90 5.73 4.55
TC 6.84 7.44 8.26 8.78 7.08 7.74 8.39 8.87 7.38 7.86 8.50 9.05
kW 0.860 0.878 0.899 0.917 0.873 0.884 0.907 0.924 0.880 0.894 0.915 0.939
CMP 0.757 0.776 0.796 0.815 0.768 0.780 0.802 0.819 0.774 0.787 0.809 0.832
LDB 44.4 47.7 52.4 57.9 46.2 48.7 53.8 59.3 47.2 49.7 54.9 60.2
LWB 41.0 46.3 51.3 57.2 41.9 47.1 52.5 58.4 42.4 48.0 53.5 59.2
105
TCG 6.44 6.95 7.89 8.77 6.63 7.13 8.22 8.85 6.89 7.25 8.33 8.95
SHG 6.44 6.02 5.21 4.30 6.63 6.32 5.48 4.39 6.89 6.57 5.66 4.49
TC 6.37 6.87 7.82 8.69 6.55 7.05 8.14 8.77 6.81 7.16 8.25 8.86
kW 0.934 0.947 0.986 1.01 0.948 0.956 0.992 1.01 0.957 0.964 1.00 1.02
CMP 0.831 0.844 0.883 0.909 0.843 0.852 0.887 0.909 0.851 0.858 0.895 0.914
LDB 46.9 49.1 53.3 58.1 48.7 50.2 54.2 59.4 49.7 51.2 55.2 60.4
LWB 42.2 47.6 52.3 57.4 43.2 48.6 53.0 58.6 43.7 49.4 53.9 59.5
115
TCG 5.96 6.26 7.28 8.42 6.15 6.39 7.42 8.61 6.41 6.50 7.53 8.72
SHG 5.96 5.71 4.94 4.16 6.15 5.98 5.15 4.31 6.41 6.22 5.33 4.42
TC 5.89 6.19 7.21 8.34 6.07 6.31 7.34 8.53 6.33 6.41 7.44 8.64
kW 1.02 1.02 1.06 1.10 1.03 1.03 1.07 1.11 1.04 1.04 1.08 1.12
CMP 0.913 0.920 0.958 1.00 0.924 0.927 0.966 1.01 0.930 0.934 0.973 1.02
LDB 49.4 50.7 54.7 58.7 51.0 51.8 55.8 59.8 51.9 52.7 56.7 60.7
LWB 43.5 49.3 53.6 58.1 44.3 50.1 54.6 59.0 44.7 50.9 55.4 59.9
125
TCG 5.43 5.67 6.45 7.60 5.68 5.79 6.55 7.72 5.89 5.92 6.65 7.81
SHG 5.43 5.43 4.60 3.86 5.68 5.69 4.79 3.98 5.89 5.91 4.97 4.09
TC 5.36 5.59 6.37 7.53 5.60 5.71 6.47 7.64 5.81 5.83 6.56 7.73
kW 1.11 1.11 1.15 1.19 1.12 1.12 1.16 1.20 1.13 1.13 1.16 1.21
CMP 1.00 1.00 1.04 1.09 1.01 1.01 1.05 1.10 1.02 1.02 1.06 1.11
LDB 52.2 52.2 56.5 60.3 53.3 53.2 57.5 61.4 54.2 54.1 58.3 62.2
LWB 44.9 50.6 55.3 59.6 45.4 51.4 56.2 60.6 45.8 52.0 56.9 61.3
Rating condition.
Not recommended for long-term operation.
LEGEND
BF Bypass Factor
CMP Compressor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Total Power
LDB Leaving Dry Bulb
LWB Leaving Wet Bulb
SHG Gross Sensible Capacity (1000 Btuh)
TC Total Net Cooling Capacity (1000 Btuh)
TCG Gross Cooling Capacity (1000 Btuh)
*Refer to Systems Index Table on page 21.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The SHG is based on 80 F edb temperature of air entering indoor
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHG.
Above 80 F edb, add (corr factor x cfm) to SHG.
Correction Factor = 1.10 x (1 BF) x (edb 80).
22