Specifications
PERFORMANCE DATA (cont)
INSTANTANEOUS AND INTEGRATED HEATING RATINGS (cont)
SYSTEM 12* — IN-CEILING CASSETTE SYSTEM (538B018 WITH 619F024)
TEMP (F)
AIR
ENTERING
INDOOR AIR
AIR
ENTERING
INDOOR UNIT
(CFM)
AIR TEMPERATURE ENTERING OUTDOOR COIL (F)
01017 203040 47 60
55
400
Cap 8.28 7.62 10.30 9.43 11.70 10.70 12.30 11.10 14.30 12.50 16.50 16.50 18.10 18.10 21.10 21.10
kW 1.46 1.50 1.53 1.54 1.58 1.61 1.63 1.65
430
Cap 8.39 7.72 10.40 9.54 11.90 10.80 12.40 11.20 14.40 12.60 16.60 16.60 18.30 18.30 21.70 21.70
kW 1.46 1.51 1.54 1.54 1.57 1.60 1.61 1.63
525
Cap 8.70 8.00 10.70 9.83 12.20 11.10 12.80 11.60 14.90 13.00 17.10 17.10 19.00 19.00 21.70 21.70
kW 1.48 1.52 1.54 1.55 1.57 1.58 1.59 1.58
60
400
Cap 7.82 7.20 9.87 9.03 11.30 10.30 11.90 10.70 13.90 12.20 16.10 16.10 17.60 17.60 20.60 20.60
kW 1.47 1.52 1.55 1.57 1.60 1.64 1.66 1.69
430
Cap 7.94 7.30 10.00 9.14 11.40 10.40 12.00 10.90 14.00 12.30 16.20 16.20 17.90 17.90 21.20 21.20
kW 1.48 1.52 1.56 1.57 1.60 1.63 1.65 1.67
525
Cap 8.24 7.58 10.30 9.44 11.80 10.80 12.40 11.20 14.50 12.70 16.70 16.70 18.50 18.50 21.40 21.40
kW 1.50 1.54 1.57 1.57 1.60 1.62 1.63 1.63
65
400
Cap 7.37 6.78 9.43 8.62 10.90 9.92 11.50 10.40 13.50 11.80 15.70 15.70 17.20 17.20 20.20 20.20
kW 1.48 1.54 1.57 1.59 1.63 1.67 1.69 1.73
430
Cap 7.48 6.88 9.56 8.75 11.00 10.10 11.60 10.50 13.70 12.00 15.80 15.80 17.40 17.40 20.70 20.70
kW 1.49 1.54 1.58 1.59 1.63 1.66 1.68 1.71
525
Cap 7.78 7.15 9.91 9.06 11.40 10.40 12.00 10.80 14.10 12.30 16.30 16.30 18.10 18.10 21.10 21.10
kW 1.51 1.56 1.59 1.60 1.63 1.65 1.66 1.68
70
400
Cap 6.91 6.35 8.99 8.22 10.50 9.53 11.10 9.98 13.10 11.50 15.20 15.20 16.80 16.80 19.80 19.80
kW 1.50 1.55 1.59 1.61 1.66 1.70 1.72 1.76
430
Cap 7.02 6.46 9.13 8.35 10.60 9.67 11.20 10.10 13.30 11.60 15.40 15.40 17.00 17.00 20.20 20.20
kW 1.50 1.56 1.60 1.61 1.65 1.69 1.71 1.75
525
Cap 7.32 6.73 9.48 8.67 11.00 10.00† 11.60 10.50 13.70 12.00 15.90 15.90 17.60 17.60† 20.80 20.80
kW 1.53 1.58 1.61 1.62 1.66 1.69 1.70 1.72
75
400
Cap 6.43 5.91 8.51 7.78 9.97 9.09 10.60 9.57 12.70 11.20 14.80 14.80 16.40 16.40 19.20 19.20
kW 1.51 1.57 1.61 1.63 1.68 1.72 1.75 1.80
430
Cap 6.53 6.01 8.65 7.91 10.10 9.24 10.80 9.71 12.90 11.30 15.00 15.00 16.60 16.60 19.50 19.50
kW 1.52 1.58 1.62 1.63 1.68 1.72 1.74 1.79
525
Cap 6.82 6.28 9.01 8.24 10.50 9.61 11.20 10.10 13.30 11.70 15.50 15.50 17.10 17.10 20.30 20.30
kW 1.54 1.60 1.63 1.64 1.68 1.72 1.73 1.76
80
400
Cap 5.95 5.47 8.04 7.35 9.50 8.66 10.20 9.16 12.30 10.80 14.40 14.40 15.90 15.90 18.60 18.60
kW 1.52 1.58 1.63 1.64 1.70 1.75 1.78 1.83
430
Cap 6.04 5.56 8.16 7.47 9.65 8.80 10.30 9.30 12.50 10.90 14.60 14.60 16.10 16.10 18.90 18.90
kW 1.53 1.59 1.63 1.65 1.70 1.75 1.78 1.82
525
Cap 6.33 5.83 8.54 7.81 10.10 9.20 10.70 9.69 12.90 11.30 15.10 15.10 16.70 16.70 19.80 19.80
kW 1.56 1.61 1.65 1.66 1.71 1.75 1.77 1.79
Indicates rating condition.
Indicates integrated rating.
LEGEND
Cap — Heating Capacity (1000 Btuh) (includes indoor-fan motor heat)
kW — Total Power Input (includes compressor motor power input, outdoor-
fan motor power input, and indoor-fan motor power input)
*Refer to Systems Index Table on page 26.
†Integrated Rating.
NOTE: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the
outdoor coil and the heat required to defrost it.
54