Specifications

PERFORMANCE DATA (cont)
INSTANTANEOUS AND INTEGRATED HEATING RATINGS (cont)
SYSTEM 3* HIGH WALL SYSTEM (538D018 WITH 619E018)
TEMP (F)
AIR
ENTERING
INDOOR UNIT
AIR
ENTERING
INDOOR UNIT
(CFM)
AIR TEMPERATURE ENTERING OUTDOOR COIL (F)
37 17 27374757
55
420
Cap 6.62 6.09 8.84 8.12 10.9 9.95 12.9 11.5 15.4 14.0 17.7 17.7 20.5 20.5
kW 1.02 1.12 1.23 1.35 1.50 1.63 1.80
450
Cap 6.70 6.16 8.93 8.21 11.0 10.0 13.0 11.6 15.5 14.1 17.9 17.9 20.6 20.6
kW 1.02 1.12 1.23 1.35 1.49 1.62 1.77
510
Cap 6.84 6.30 9.11 8.37 11.2 10.2 13.3 11.8 15.8 14.4 18.2 18.2 20.7 20.7
kW 1.02 1.12 1.23 1.34 1.47 1.59 1.73
60
420
Cap 6.19 5.69 8.29 7.62 10.6 9.65 12.6 11.1 15.0 13.6 17.3 17.3 19.9 19.9
kW 1.03 1.14 1.25 1.37 1.52 1.67 1.83
420
Cap 6.27 5.77 8.40 7.72 10.7 9.74 12.7 11.3 15.1 13.8 17.5 17.5 20.1 20.1
kW 1.03 1.14 1.25 1.37 1.52 1.65 1.81
510
Cap 6.41 5.90 8.65 7.95 10.9 9.91 12.9 11.5 15.4 14.0 17.8 17.8 20.6 20.6
kW 1.03 1.14 1.25 1.36 1.50 1.63 1.79
65
420
Cap 5.75 5.29 7.84 7.20 10.2 9.30 12.2 10.8 14.6 13.2 16.8 16.8 19.7 19.7
kW 1.04 1.15 1.27 1.40 1.55 1.70 1.88
450
Cap 5.83 5.36 7.94 7.30 10.3 9.40 12.3 10.9 14.7 13.4 17.0 17.0 19.8 19.8
kW 1.04 1.15 1.27 1.39 1.54 1.69 1.86
510
Cap 5.96 5.49 8.12 7.46 10.5 9.58 12.5 11.1 15.0 13.6 17.4 17.4 20.1 20.1
kW 1.05 1.15 1.27 1.39 1.53 1.67 1.83
70
420
Cap 5.30 4.88 7.37 6.77 9.63 8.78 11.8 10.5 14.1 12.9 16.4 16.4 19.2 19.2
kW 1.05 1.17 1.29 1.42 1.58 1.73 1.92
450
Cap 5.38 4.95 7.46 6.85 9.80 8.94 12.0 10.6 14.3 13.0 16.6 16.6 19.3 19.3
kW 1.05 1.17 1.29 1.41 1.57 1.72 1.90
510
Cap 5.52 5.08 7.66 7.04 10.1 9.17† 12.2 10.8 14.6 13.3 16.9 16.9† 19.8 19.8
kW 1.06 1.17 1.28 1.41 1.56 1.70 1.87
75
420
Cap 4.86 4.47 6.89 6.33 9.09 8.29 11.4 10.2 13.7 12.5 16.0 16.0 18.7 18.7
kW 1.06 1.18 1.30 1.44 1.60 1.76 1.96
450
Cap 4.93 4.53 6.98 6.42 9.22 8.41 11.6 10.3 13.9 12.6 16.2 16.2 19.0 19.0
kW 1.06 1.18 1.30 1.43 1.59 1.75 1.94
510
Cap 5.06 4.65 7.16 6.58 9.50 8.66 11.8 10.5 14.2 12.9 16.5 16.5 19.3 19.3
kW 1.07 1.18 1.30 1.43 1.59 1.74 1.91
80
420
Cap 5.31 4.89 6.42 5.90 8.58 7.82 11.0 9.79 13.3 12.1 15.6 15.6 18.2 18.2
kW 1.07 1.19 1.32 1.46 1.62 1.79 1.99
450
Cap 5.38 4.95 6.50 5.97 8.71 7.94 11.2 9.93 13.3 12.3 15.8 15.8 18.5 18.5
kW 1.07 1.19 1.32 1.45 1.61 1.78 1.98
510
Cap 5.50 5.06 6.67 6.13 8.94 8.15 11.4 10.1 13.7 12.5 16.1 16.1 18.9 18.9
kW 1.08 1.19 1.32 1.45 1.61 1.77 1.96
Indicates rating condition.
Indicates integrated rating.
LEGEND
Cap Heating Capacity (1000 Btuh) (includes indoor-fan motor heat)
kW Total Power Input (includes compressor motor power input, outdoor-
fan motor power input, and indoor-fan motor power input)
*Refer to Systems Index Table on page 26.
†Integrated Rating.
NOTE: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the
outdoor coil and the heat required to defrost it.
45