Specifications

PERFORMANCE DATA (cont)
COOLING CAPACITIES (cont)
SYSTEM 14* IN-CEILING CASSETTE SYSTEM (538B030 WITH 619F036)
TEMP (F)
AIR ENTERING
OUTDOOR UNIT
(Edb)
AIR ENTERING INDOOR UNIT CFM/BF
635/0.06 745/0.07 915/0.09
Air Entering Indoor Unit Ewb (F)
57 62 67 72 57 62 67 72 57 62 67 72
55
TCG 28.0 30.4 32.7 33.8 29.7 31.3 33.5 34.6 31.5 32.3 34.1 35.1
SHG 28.0 24.8 20.8 16.4 29.7 26.6 22.0 17.0 31.5 29.0 23.3 17.7
TC 27.7 30.1 32.4 33.5 29.3 31.0 33.1 34.2 31.1 31.8 33.6 34.6
kW 1.70 1.71 1.73 1.74 1.72 1.73 1.76 1.77 1.77 1.76 1.78 1.80
CMP 1.44 1.45 1.47 1.48 1.44 1.46 1.48 1.49 1.46 1.46 1.48 1.50
LDB 41.3 45.9 51.4 57.6 45.1 48.8 54.3 60.2 49.9 52.4 57.9 63.3
LWB 39.4 44.7 50.3 56.8 41.3 47.1 52.8 59.0 43.7 49.9 55.6 61.6
65
TCG 26.9 29.1 31.5 33.0 28.5 30.0 32.3 33.8 30.4 31.0 33.0 34.4
SHG 26.9 24.0 20.2 16.1 28.5 25.9 21.5 16.8 30.4 28.5 23.1 17.6
TC 26.6 28.7 31.1 32.7 28.1 29.6 31.9 33.4 29.9 30.5 32.6 34.0
kW 1.89 1.91 1.93 1.94 1.92 1.93 1.95 1.97 1.96 1.96 1.99 2.00
CMP 1.63 1.65 1.67 1.68 1.64 1.65 1.68 1.70 1.66 1.66 1.69 1.70
LDB 42.5 46.6 51.9 57.8 46.2 49.3 54.6 60.3 50.7 52.6 57.8 63.2
LWB 40.0 45.4 50.9 57.0 41.9 47.7 53.2 59.2 44.1 50.3 55.8 61.7
75
TCG 25.8 27.7 30.2 32.2 27.3 28.6 31.1 32.9 29.3 29.7 32.0 33.8
SHG 25.8 23.3 19.7 15.8 27.3 25.2 21.0 16.5 29.3 27.9 22.8 17.5
TC 25.5 27.4 29.9 31.9 27.0 28.3 30.7 32.6 28.8 29.3 31.5 33.3
kW 2.08 2.10 2.12 2.15 2.11 2.13 2.15 2.17 2.16 2.16 2.19 2.21
CMP 1.82 1.84 1.87 1.89 1.84 1.85 1.88 1.90 1.86 1.87 1.89 1.91
LDB 43.7 47.2 52.4 57.9 47.2 49.8 54.9 60.4 51.5 52.8 57.8 63.1
LWB 40.6 46.1 51.4 57.3 42.4 48.3 53.6 59.5 44.5 50.7 56.1 61.8
85
TCG 24.7 26.3 29.0 31.4 26.2 27.3 29.9 32.1 28.1 28.5 30.9 33.1
SHG 24.7 22.5 19.1 15.5 26.2 24.6 20.6 16.2 28.1 27.4 22.6 17.4
TC 24.4 26.0 28.7 31.1 25.8 26.9 29.6 31.7 27.7 28.0 30.5 32.6
kW 2.27 2.29 2.32 2.35 2.31 2.32 2.35 2.38 2.35 2.36 2.39 2.42
CMP 2.01 2.04 2.07 2.10 2.04 2.05 2.08 2.10 2.06 2.07 2.09 2.12
LDB 44.8 47.9 52.8 58.1 48.2 50.2 55.1 60.5 52.3 53.0 57.8 63.0
LWB 41.2 46.8 51.9 57.5 42.9 48.8 54.0 59.7 44.9 51.0 56.3 61.9
95
TCG 23.6 24.9 27.6 30.1 25.0 25.8 28.5 30.9 26.7 26.9 29.4 31.7
SHG 23.6 21.7 18.5 15.0 25.0 23.7 19.9 15.8 26.7 26.4 22.0 16.9
TC 23.3 24.6 27.3 29.8 24.6 25.4 28.1 30.6 26.3 26.5 29.0 31.3
kW 2.49 2.51 2.55 2.59 2.53 2.54 2.58 2.61 2.59 2.59 2.62 2.65
CMP 2.23 2.26 2.30 2.33 2.26 2.27 2.31 2.34 2.29 2.30 2.33 2.36
LDB 46.0 48.7 53.5 58.6 49.4 50.9 55.7 60.8 53.4 53.7 58.2 63.3
LWB 41.8 47.5 52.6 58.0 43.5 49.5 54.6 60.0 45.4 51.6 56.8 62.2
105
TCG 22.5 23.5 26.0 28.6 23.8 24.4 26.8 29.4 25.4 25.4 27.7 30.2
SHG 22.5 21.0 17.7 14.3 23.8 22.9 19.2 15.2 25.4 25.4 21.2 16.4
TC 22.2 23.2 25.7 28.3 23.4 24.0 26.5 29.0 25.0 25.0 27.3 29.8
kW 2.73 2.75 2.80 2.84 2.77 2.79 2.83 2.87 2.83 2.83 2.87 2.91
CMP 2.48 2.50 2.55 2.59 2.51 2.52 2.57 2.60 2.54 2.54 2.58 2.62
LDB 47.2 49.4 54.3 59.2 50.5 51.6 56.3 61.3 54.4 54.4 58.7 63.6
LWB 42.4 48.3 53.4 58.6 44.0 50.1 55.3 60.5 45.9 52.1 57.3 62.6
115
TCG 21.4 22.2 24.4 27.1 22.6 22.9 25.2 27.8 24.1 24.1 26.0 28.6
SHG 21.4 20.2 17.0 13.7 22.6 22.1 18.4 14.6 24.1 24.1 20.5 15.8
TC 21.1 21.9 24.1 26.8 22.3 22.6 24.8 27.5 23.6 23.7 25.6 28.2
kW 3.01 3.03 3.08 3.12 3.05 3.06 3.11 3.15 3.11 3.11 3.16 3.19
CMP 2.76 2.77 2.83 2.87 2.78 2.79 2.85 2.88 2.82 2.82 2.87 2.90
LDB 48.5 50.2 55.0 59.9 51.6 52.3 57.0 61.8 55.4 55.4 59.2 64.0
LWB 43.0 49.0 54.1 59.3 44.6 50.7 55.9 61.1 46.4 52.5 57.9 63.1
125
TCG 20.2 20.8 23.0 25.5 21.4 21.5 23.7 26.2 22.8 22.8 24.4 26.9
SHG 20.2 19.4 16.3 13.1 21.4 21.2 17.7 14.0 22.8 22.8 19.7 15.2
TC 19.9 20.5 22.7 25.2 21.1 21.2 23.4 25.8 22.4 22.4 23.9 26.5
kW 3.31 3.32 3.38 3.42 3.35 3.35 3.41 3.46 3.41 3.41 3.45 3.50
CMP 3.06 3.07 3.13 3.17 3.09 3.09 3.15 3.19 3.12 3.12 3.17 3.21
LDB 49.8 51.0 55.8 60.6 52.8 53.1 57.6 62.4 56.5 56.4 59.8 64.5
LWB 43.7 49.7 54.8 60.0 45.2 51.3 56.5 61.7 46.9 53.0 58.4 63.5
Rating condition.
LEGEND
BF Bypass Factor
CMP Compressor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Total Power
LDB Leaving Dry Bulb
LWB Leaving Wet Bulb
SHG Gross Sensible Capacity (1000 Btuh)
TC Total Net Cooling Capacity (1000 Btuh)
TCG Gross Cooling Capacity (1000 Btuh)
*Refer to Systems Index Table on page 26.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The SHG is based on 80 F edb temperature of air entering indoor
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHG.
Above 80 F edb, add (corr factor x cfm) to SHG.
Correction Factor = 1.10 x (1 BF) x (edb 80).
40