Specifications

PERFORMANCE DATA (cont)
COOLING CAPACITIES
SYSTEM 1* HIGH WALL SYSTEM (538B009 WITH 619E009)
TEMP (F)
AIR ENTERING
OUTDOOR UNIT
(Edb)
AIR ENTERING INDOOR UNIT CFM/BF
214/0.10 233/0.11 252/0.12
Air Entering Indoor Unit Ewb (F)
57 62 67 72 57 62 67 72 57 62 67 72
55
TCG 8.57 8.95 9.57 9.71 8.79 9.04 9.60 10.0 8.97 9.07 9.61 9.94
SHG 8.49 7.17 6.05 4.74 8.79 7.36 6.13 4.91 8.97 7.48 6.20 4.91
TC 8.52 8.89 9.52 9.65 8.72 8.97 9.53 9.95 8.90 9.00 9.54 9.87
kW 0.61 0.62 0.63 0.64 0.62 0.62 0.63 0.65 0.62 0.62 0.64 0.65
CMP 0.51 0.52 0.54 0.54 0.52 0.52 0.54 0.55 0.52 0.52 0.54 0.55
LDB 43.0 48.8 53.7 59.5 44.9 50.6 55.6 60.5 46.8 52.4 57.2 62.0
LWB 40.0 46.1 51.8 58.4 41.2 47.4 53.2 59.3 42.2 48.7 54.4 60.5
65
TCG 8.42 8.85 9.59 10.0 8.65 8.97 9.67 10.1 8.83 9.07 9.73 10.0
SHG 8.42 7.21 6.13 4.90 8.65 7.44 6.27 4.95 8.83 7.67 6.39 4.96
TC 8.36 8.79 9.53 9.97 8.58 8.90 9.61 10.0 8.76 9.00 9.66 9.93
kW 0.68 0.69 0.71 0.72 0.69 0.70 0.72 0.73 0.69 0.70 0.72 0.73
CMP 0.58 0.59 0.62 0.63 0.59 0.60 0.62 0.63 0.59 0.60 0.62 0.63
LDB 43.3 48.7 53.4 58.8 45.4 50.3 55.0 60.3 47.4 51.7 56.5 61.8
LWB 40.4 46.3 51.8 57.9 41.5 47.6 53.1 59.2 42.5 48.7 54.2 60.4
75
TCG 8.25 8.64 9.42 9.92 8.45 8.78 9.54 9.94 8.65 8.89 9.65 9.94
SHG 8.25 7.16 6.09 4.86 8.45 7.44 6.27 4.91 8.65 7.69 6.45 4.96
TC 8.19 8.58 9.36 9.86 8.38 8.71 9.48 9.87 8.58 8.82 9.58 9.87
kW 0.76 0.77 0.80 0.81 0.77 0.78 0.80 0.81 0.78 0.78 0.81 0.81
CMP 0.67 0.68 0.70 0.71 0.67 0.68 0.70 0.71 0.68 0.68 0.71 0.71
LDB 44.1 48.8 53.6 58.9 46.2 50.3 55.0 60.5 48.1 51.6 56.2 61.8
LWB 40.8 46.8 52.1 58.1 41.9 47.9 53.3 59.4 42.8 49.0 54.3 60.5
85
TCG 8.05 8.43 9.15 9.68 8.26 8.54 9.29 9.77 8.44 8.66 9.40 9.78
SHG 8.05 7.13 6.00 4.77 8.26 7.39 6.21 4.87 8.44 7.68 6.40 4.93
TC 7.99 8.37 9.09 9.62 8.19 8.47 9.22 9.70 8.37 8.59 9.33 9.71
kW 0.85 0.86 0.89 0.90 0.86 0.87 0.89 0.91 0.87 0.87 0.90 0.91
CMP 0.76 0.77 0.79 0.81 0.76 0.77 0.80 0.81 0.77 0.77 0.80 0.81
LDB 44.9 49.0 53.9 59.3 47.0 50.5 55.3 60.6 48.8 51.7 56.4 61.9
LWB 41.2 47.2 52.6 58.5 42.3 48.4 53.7 59.6 43.2 49.3 54.7 60.7
95
TCG 7.68 8.12 8.83 9.40 7.95 8.26 8.96 9.47 8.18 8.38 9.07 9.54
SHG 7.68 7.02 5.88 4.67 7.95 7.32 6.09 4.77 8.18 7.62 6.29 4.86
TC 7.62 8.06 8.77 9.34 7.89 8.19 8.89 9.41 8.11 8.31 9.00 9.47
kW 0.95 0.96 0.99 1.01 0.96 0.97 0.99 1.01 0.97 0.97 1.00 1.01
CMP 0.85 0.87 0.89 0.91 0.86 0.87 0.90 0.91 0.87 0.88 0.90 0.92
LDB 46.6 49.5 54.5 59.8 48.2 50.8 55.7 61.1 49.8 51.9 56.8 62.2
LWB 42.1 47.8 53.2 59.0 42.9 48.9 54.3 60.1 43.7 49.8 55.2 61.0
105
TCG 7.21 7.53 8.48 9.11 7.47 7.68 8.58 9.21 7.70 7.82 8.69 9.30
SHG 7.21 6.75 5.75 4.57 7.47 7.07 5.96 4.69 7.70 7.37 6.16 4.81
TC 7.15 7.47 8.42 9.05 7.41 7.62 8.52 9.15 7.63 7.74 8.62 9.23
kW 1.05 1.06 1.10 1.12 1.06 1.07 1.11 1.13 1.07 1.08 1.11 1.13
CMP 0.96 0.97 1.00 1.03 0.97 0.97 1.01 1.03 0.98 0.98 1.01 1.04
LDB 48.6 50.7 55.0 60.2 50.2 51.8 56.3 61.4 51.6 52.8 57.3 62.4
LWB 43.1 49.0 53.8 59.4 43.9 49.9 54.9 60.4 44.6 50.7 55.7 61.3
115
TCG 6.72 6.88 7.79 8.76 6.96 7.01 7.94 8.88 7.17 7.15 8.04 8.97
SHG 6.72 6.45 5.47 4.45 6.96 6.75 5.70 4.59 7.17 7.04 5.91 4.71
TC 6.66 6.82 7.73 8.70 6.89 6.95 7.87 8.81 7.10 7.08 7.97 8.90
kW 1.17 1.17 1.21 1.25 1.18 1.18 1.22 1.26 1.19 1.19 1.23 1.27
CMP 1.07 1.08 1.12 1.16 1.08 1.09 1.12 1.16 1.09 1.09 1.13 1.17
LDB 50.8 52.0 56.3 60.7 52.2 53.1 57.3 61.8 53.6 54.1 58.2 62.7
LWB 44.2 50.2 55.0 60.0 44.9 51.1 55.9 60.9 45.5 51.8 56.7 61.7
125
TCG 6.18 6.23 7.02 8.03 6.41 6.37 7.14 8.15 6.61 6.52 7.23 8.26
SHG 6.18 6.14 5.15 4.19 6.41 6.37 5.38 4.33 6.61 6.52 5.60 4.47
TC 6.13 6.17 6.96 7.97 6.34 6.31 7.07 8.09 6.54 6.45 7.16 8.19
kW 1.30 1.30 1.34 1.39 1.31 1.31 1.34 1.39 1.32 1.32 1.35 1.40
CMP 1.20 1.20 1.24 1.29 1.21 1.21 1.25 1.30 1.22 1.22 1.25 1.30
LDB 53.1 53.3 57.7 61.9 54.4 54.6 58.6 62.8 55.6 56.0 59.4 63.6
LWB 45.3 51.5 56.3 61.1 46.0 52.2 57.1 61.9 46.5 52.8 57.8 62.6
Rating condition.
Not recommended for long-term operation.
LEGEND
BF Bypass Factor
CMP Compressor
Edb Entering Dry Bulb
Ewb Entering Wet Bulb
kW Total Power
LDB Leaving Dry Bulb
LWB Leaving Wet Bulb
SHG Gross Sensible Capacity (1000 Btuh)
TC Total Net Cooling Capacity (1000 Btuh)
TCG Gross Cooling Capacity (1000 Btuh)
*Refer to Systems Index Table on page 26.
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The SHG is based on 80 F edb temperature of air entering indoor
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHG.
Above 80 F edb, add (corr factor x cfm) to SHG.
Correction Factor = 1.10 x (1 BF) x (edb 80).
27