Installation manual
15
ATC32U01A Communicating, Programmable Thermostat - IOM
Created: 1 Oct., 2012
YF036 S N - - - - - 0 1 2 3
LAST 5 FAULTS
LT1 LOW WATER TEMP
NO FAULT
NO FAULT
NO FAULT
NO FAULT
NEXT
PREVIOUS SELECT
9.7 MULT-UNIT FAULT INFO
When multiple units are connected to one thermostat,
UNLIKE Mult-Unit Diagnostics, the service personnel views
each units’ fault information by selecting the next option.
10.0 Restore Defaults
The thermostat will reset all settings, excluding the
thermostat confi guration settings (section 2), to their factory
defaults.
CONTROL DIAGNOSTICS
YF024 S N - - - - - 1 2 3 4
YF024 S N - - - - - 5 6 7 8
YF036 S N - - - - - 9 0 1 2
PREVIOUS SELECT