Installation manual

Optional Timers
Timers should be present when the HRV/ERV is exhausting from
speciific locations i.e bathrooms, laundry rooms. The Digital
Electronic Timer is the best selection, however, the crank timer will
be necessary if only 2 lead low voltage wires are present.
19
AIR SENTRY™ Air Quality Sensor
PART NO. 99-109
Connects to RED, GREEN and YELLOW terminals. Use a minimum
of three lead 20 gauge low voltage wire. 100 ft (30 m) maximum
wire length. Only compatible with ControlAir-15 electronics.
A
IR
I R
S
ENTRY
E NT RY
D
IGITAL
IG ITA L
A
IR
IR
Q
UALITY
UA LI TY
S
ENSOR
EN SO R
FAN SPEED
IND
I
CATOR
FAN S P
EE D IN DI CA
TO R
Digital Electronic Timer (DET)
PART NO. 99-104
Connects to RED, GREEN and YELLOW terminals. Use a mini-
mum of three 20 gauge low voltage wire. Connect up to 8 on 300 ft
(91 m) wire max. Connect up to 5 on 300 ft (91 m) wire if Air Sentry
is used. Mounts ina2x4box. Shown with a ‘decora’ cover plate
(99-107W).
Ventilation Dehumidistat
PART NO. 99-250
Connects to BLACK, RED, GREEN and YELLOW terminals. Use a
minumum of four lead 20 gauge low voltage wire.
*Only compatible with ControlAir-15 electronics.
Lifestyle Ventilation Control
PART NO. 99-350
Connects to RED, GREEN and YELLOW terminals. Use a
minumum of three lead 20 gauge low voltage wire.
*Only compatible with ControlAir-15 electronics manufactured after
November 1, 2006.
The Lifestyle Ventilation Control allows you to program when and
how much fresh air will be entering your home.
VENTILATION
DEHUMIDISTAT
Crank Timer
PART NO. 99-101
Connects to RED and ORANGE terminals. Use a two 20 gauge
low voltage wire. Mounts ina2x4box. The crank timer provides a
solution to installing a system where only 2 wires are present for
the timers.
Off
10
20
30
40
50
60
ControlAir-15 Optional Remote Controls
Optional Main Controls
The amount of ventilation required in your home will fluctuate
according to the activity level in the house. Higher activity levels
require more ventilation.
Main controls can be mounted in a central location of the home (i.e.
beside the furnace thermostat) which will provide the user with com-
plete control over their ventilation system from a convenient location.
Only one main control can be installed on your
system.
ATTENTION
Dehumidistat Dial
The dehumidistat is used to
reduce high winter humidity lev-
els. The dehumidistat activates
high speed ventilation when the
indoor humidity level exceeds
selected setting.
Key Features
24/7 programmable ventilation
4 programmable events
Simple to program
Electronic dehumidistat
5 speeds, 4 modes of operation
Easy to read LCD screen
Knockout for the Control Pad
The control pad from the HRV/ERV fits
into this knockout giving full functionality
and control of the HRV/ERV from a
remote location.
Knockout for the Control Pad
The control pad from the HRV/ERV fits
into this knockout giving full functionali-
ty and control of the HRV/ERV from a
remote location.
Status Light
The status light indicates the
increased fan speed when the Air
Quality Sensor reacts to odors and
contaminants. A slow flashing light
indicates low contamination (medi-
um speed ventilation) while a fast
flashing light indicates high conta-
mination (high speed ventilation).
The Air Quality Sensor detects
gases such as cigarette smoke
and formaldehyde. The sensitivity
level of the sensor is adjustable.
Touch Pad
The Touch Pad initiates
high speed operation.
20/40/60 Minute Status Lights
The 20/40/60 Minute Status
Lights indicate the time high
speed operation will be activated.
Crank Dial
Rotate the dial for up to 60
minutes high speed operation.
T
AM
FAN
VENT
RH
PROGRAM
RUN
11 26
2
40
MODE
SET
FAN
OFF / ON
V
e
n
t
i
l
a
t
i
o
n
C
o
n
t
r
o
l