Unoccupied Settings
UNOCCUPIED operation allows you to select maximum and mini-
mum temperatures, humidity levels, fan speed and ventilator speed
for times when your home will be unoccupied for a designated
period of time. These settings will apply to all zones when activated.
1 Open the door of the Evolution
®
Control.
2 Press the ADVANCED setup button to view 1st ADVANCED
setup display (1 of 7).
3 Press the LEFT button twice to select the UNOCCUPIED display
(6 of 7).
4 Use the Right Up/Down button to set your MAX TEMPERATURE.
5 Press DOWN on the SCROLL button to highlight MIN
TEMPERATURE.
6
Use the Right Up/Down button to select MIN TEMPERA
TURE.
7 Press DOWN on the SCROLL button to highlight MAX HUMIDITY.
8 Use the Right Up/Down button to set MAX HUMIDITY.
9 Press DOWN on the SCROLL button to highlight MIN HUMIDITY.
10 Use the Right Up/Down button to select MIN HUMIDITY.
11 Press DOWN on the SCROLL button to highlight FAN mode.
Use the Right Up/Down button to select FAN mode: LOW, MED,
HIGH or AUTO.
12 Press DOWN on the SCROLL button to highlight VENTILATOR
mode. Use the Right Up/Down button to select VENTILATOR
mode: LOW, MED, HIGH OR AUTO.
13 To exit, press ADVANCED or simply close the door.