Manual

4
ACCESSORY THERMOSTAT S
THERMOSTAT / SUBBASE PKG. DESCRIPTION
TSTATBBPRH01---B Thermidistat Control --- Programmable / Non--- Programmable Thermostat with Humidity control
TSTATBBPAC01--- B T h e r m o s t a t --- A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e , _F/_C , 1 --- S t a g e H e a t , 1 --- S t a g e C o o l
TSTATBBNAC01---C T h e r m o s t a t --- A u t o C h a n g e o v e r, N o n --- P r o g r a m m a b l e , _F/_C , 1 --- S t a g e H e a t , 1 --- S t a g e C o o l
TSTATBBBAC01---B Builder’s Thermostat --- Manual C hangeover, Non---Programmable, _F/_C , 1 --- S t a g e H e a t , 1 --- S t a g e C o o l
TSTATBBSEN01--- B Outdoor Air Temperature Sensor
TSTATXXBBP01 Backplate f or Builder’s Thermostat
TSTATXXNBP01 Backplate for Non ---Programmable Thermostat
TSTATXXPBP01 Backplate for Programmable Thermostat
TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wires) --- 10 Pack
ACCESSORIES
KIT NUMBER DESCRIPTION
Size --- Voltage & Series
18--- 30 24--- 30 30--- 30 36 --- 30 42 --- 30 48--- 30 60 --- 30
KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X
KAAT D0101TDR TIME DELAY RELAY X X X X X X X
KAAWS0101AAA WINTER START X X X X X X X
KSALA0301410 LOW AMBIENT PSW X X X X X X X
KSALA0601AAA MOTORMASTER 230V X X X X X X X
HC32GE234 MOTOR FAN BALL BEARING X
HC34GE239 MOTOR FAN BALL BEARING X X
HC40GE226 MOTOR FAN BALL BEARING X X
HC38GE219 MOTOR FAN BALL BEARING X
HC40GE228 MOTOR FAN BALL BEARING X
KSAHS1701AAA HARD START (CAP / RELAY) X X X X X X X
KSACY0101AAA CYCLE PROTECTOR X X X X X X X
KSASF0101AAA SUPPORT FEET X X X X X X X
KAACS0201PTC START ASSIST PT C X X X X X X X
KAACH1201AAA CRANKCASE HTR X X X
KAACH1401AAA CRANKCASE HTR X X X X
KSATX0201PUR TXV PURON HSO X X X
KSATX0301PUR TXV PURON HSO X X
KSATX0401PUR TXV PURON HSO X
KSATX0501PUR TXV PURON HSO X
KSASH1801COP SOUND HOOD X X X X
KSASH0601COP SOUND HOOD X X
KSASH2101COP SOUND HOOD X
KAALP0301PUR LOW PRES SURE SWITCH X X X X X X X
KAAHI0401PUR HIGH PRES SURE SWITCH X X X X X X X
ACCESSORY USAGE GUIDELINE
ACCESSORY
REQUIRED FOR LOW---AMBIENT
COOLING APPLICATIONS
(Below 55° F)
REQUIRED FOR
LONG LINE
APPLICATIONS*
(Over 80 Ft.)
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles)
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Accumulator No No No
Compressor Start Assist Capacitor and Relay Yes Yes No
Motor Master
®
Control or Low---ambient
Pressure Switch
Yes No No
Support Feet Recommended No Recommended
Liquid Line Solenoid Valve No
S e e L o n g --- L i n e A p -
plication Guideline
No
Ball Bearing Fan Motor Yes{ No No
* For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differntial, refer to Residential Split---System Longline Application Guideline.
{ Required for Low---Ambient Controller (full modulation feature) and MotorMasterr Control only.
113A