COMBINATION RATINGS CONTINUED
Unit Size ---
Voltage &
Series
Indoor
Model
To t a l C a p .
BTUH
Factory
Supplied
Enhancement
SEER
EER
Furnace
Model
Standard
Rating
TDR{
048--- A
CNPH*4821A** 45,000 TDR&TXV 13.50 11.20 315(A,J)AV048090
CNPH*4821A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV060110
CNPH*6024A** 47,000 TXV 13.20 11.00
CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 355AAV060080
CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 355AAV060100
CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 315(A,J)AV048090
CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 315(A,J)AV060110
CNPF*4818A** 45,000 TXV 13.00 11.00
CSPH*4812A** 46,000 TXV 13.00 11.00
CSPH*4812A** 45,000 TDR&TXV 13.20 11.00 355AAV060080
CSPH*4812A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV048090
CSPH*6012A** 47,000 TXV 13.20 11.00
CSPH*6012A** 46,000 TDR&TXV 13.50 11.20 355AAV060080
CSPH*6012A** 46,000 TDR&TXV 13.50 11.20 315(A,J)AV048090
FX4CN(B,F)048 47,000 TDR&TXV 13.50 11.20
FX4CN(B,F)060 47,500 TDR&TXV 14.00 11.50
FV4BNF005 46,500 TDR&TXV 14.00 11.50
FV4BNB006 47,000 TDR&TXV 14.00 11.70
FY4ANF048 46,000 TDR&TXV 13.00 11.00
FY4ANB060 46,500 TDR&TXV 13.20 11.00
060--- A
CAP**6021A** 56,500 TXV 13.00 11.00
CAP**6021A** 56,000 TDR&TXV 13.20 11.00 315(A,J)AV060110
*CAP**6024A** 57,500 TXV 13.00 11.00
CAP**6024A** 56,500 TDR&TXV 13.20 11.00 315(A,J)AV066135
CAP**6024A** 56,500 TDR&TXV 13.50 11.20 315(A,J)AV066155
CNPV*6024A** 57,000 TXV 13.00 11.00
CNPV*6024A** 56,000 TDR&TXV 13.50 11.00 315(A,J)AV066135
CNPV*6024A** 56,500 TDR&TXV 13.50 11.20 315(A,J)AV066155
CNPH*6024A** 57,000 TXV 13.00 11.00
CNPH*6024A** 56,000 TDR&TXV 13.50 11.20 315(A,J)AV066135
CNPH*6024A** 56,500 TDR&TXV 13.50 11.20 315(A,J)AV066155
CSPH*6012A** 57,500 TXV 13.00 11.00
CSPH*6012A** 56,500 TDR&TXV 13.20 11.00 315(A,J)AV060110
CSPH*6012A** 56,500 TDR&TXV 13.50 11.20 315(A,J)AV066135
CSPH*6012A** 56,500 TDR&TXV 13.50 11.20 315(A,J)AV066155
FX4CN(B,F)060 58,000 TDR&TXV 13.20 11.00
FV4BNB006 57,000 TDR&TXV 13.50 11.20
FY4ANB060 56,500 TDR&TXV 13.00 11.00
* Tested combination
{ In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time---Delay Relay KAATD0101TDR or a fu rnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
EER Energy Efficiency Ra tio
SEER Seasonal Energy Efficiency Ratio
TDR T i m e --- D e l a y R e l a y
TXV Thermostatic Expansion Valve
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
113A