Product data
13
PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR (CONT)
Cooling Extended Performance Table
704C048
Temp (°F)
Outdoor Air
Entering Condenser
Evaporator Air --- CFM/BF
1400/ 0.06 1600 / 0.08
Evaporator Air Ewb (°F)
62 63* 67 72 62 63* 67 72
75
TC 44.7 45.3 49.0 53.9 46.0 46.6 50.3 55.3
SHC 40.8 32.8 34.3 27.6 43.9 35.2 36.7 29.3
kW 3.3 3.3 3.3 3.4 3.3 3.3 3.4 3.4
85
TC 42.4 43.0 46.5 51.2 43.7 44.1 47.7 52.4
SHC 39.6 31.7 33.2 26.5 42.4 34.0 35.7 28.2
kW 3.7 3.7 3.7 3.8 3.7 3.7 3.7 3.8
95
TC 40.0 40.6 44.0 48.5 42.3 41.8 45.0 49.5
SHC 38.2 30.6 32.2 25.5 41.1 33.1 34.5 27.1
kW 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.2
105
TC 37.9 38.1 41.2 45.5 39.7 39.1 42.1 46.4
SHC 36.6 29.4 30.9 24.4 38.3 31.8 33.3 25.8
kW 4.5 4.5 4.5 4.6 4.5 4.5 4.5 4.6
115
TC 36.6 35.5 38.3 42.3 37.1 36.2 39.1 43.0
SHC 34.1 28.2 29.6 23.2 36.6 30.4 32.0 24.7
kW 5.0 4.9 5.0 5.0 5.0 5.0 5.0 5.0
125
TC 33.1 32.6 35.3 38.8 34.6 33.3 35.9 39.5
SHC 32.4 27.0 28.4 21.9 34.1 28.9 30.6 23.3
kW 5.5 5.4 5.5 5.5 5.5 5.5 5.5 5.5
Cooling Extended Performance Table
704C060
Temp (°F)
Outdoor Air
Entering Condenser
Evaporator Air --- CFM/BF
1750/ 0.007 2000 / 0.01
Evaporator Air Ewb (°F)
62 63* 67 72 62 63* 67 72
75
TC 58.8 59.7 64.0 69.8 60.0 60.8 64.9 70.8
SHC 53.6 51.8 44.5 35.4 57.6 55.4 47.1 36.8
kW 4.2 4.3 4.3 4.4 4.4 4.4 4.5 4.6
85
TC 56.2 57.0 61.1 66.6 57.4 58.1 61.9 67.4
SHC 52.4 50.5 43.2 34.2 56.3 54.2 45.8 35.6
kW 4.7 4.7 4.8 4.9 4.8 4.9 5.0 5.0
95
TC 53.5 54.3 58.0 63.2 55.0 55.3 58.7 64.1
SHC 51.1 49.2 41.9 32.9 55.0 52.9 44.5 34.4
kW 5.1 5.2 5.3 5.3 5.2 5.3 5.5 5.5
105
TC 50.7 51.4 54.8 59.6 52.5 52.4 55.4 60.2
SHC 49.8 47.9 40.6 31.6 52.5 51.6 43.2 33.0
kW 5.7 5.7 5.8 5.9 5.8 5.8 6.0 6.1
115
TC 48.1 48.3 51.3 56.8 49.7 49.7 51.8 57.0
SHC 48.1 46.6 39.2 30.6 49.7 49.7 41.8 31.7
kW 6.2 6.3 6.4 6.4 6.4 6.4 6.6 6.6
125
TC 45.2 45.1 47.4 52.5 46.4 46.4 47.9 52.2
SHC 45.2 45.1 37.6 28.9 46.4 46.4 40.2 29.7
kW 6.8 6.9 7.0 7.0 7.0 7.0 7.2 7.2
See page 14 for cooling notes.
704C