User Guide
Table Of Contents
- Product Data
- Features/Benefits
- Model Number Nomenclature
- AHRI Capacities
- Unit Dimensions
- Unit Dimensions
- 36-60
- Accessory Dimensions
- 1. Roof curb must be set up for unit being installed.
- 2. Seal strip must be applied, as required, to unit being installed.
- 3. Roof curb is made of 16-gauge steel.
- 4. Attach ductwork to curb (flanges of duct rest on curb).
- 5. Insulated panels: 1-in. (25.4 mm) thick fiberglass 1 lb. density.
- Performance Data
- Application Data
- Electrical Data
- Connection Wiring Schematic 208/230-1-60
- Controls
- Operating Sequence
- 2. The normally open contacts of energized contactor (C) close and complete the circuit through compressor motor (COMP) to condenser (outdoor) fan motor (OFM). Both motors start instantly.
- 3. The set of normally open contacts on the interface fan board (IFB) are closed which energizes a circuit to the indoor fan motor (IFM).
- Guide Specifications
- Packaged Gas Heating/Electric Cooling Units Constant Volume Application
- HVAC Guide Specifications
- General
- Products
- Guide Specifications (Continued)
- 2. Compressor Start Kit (single phase units only):
- 3. Thermostat:
- 4. Crankcase Heater:
- 5. Economizer:
- 6. Filter Rack Kit:
- 7. Flat Roof Curb:
- 8. Flue Discharge Deflector
- 9. Low Ambient Package:
- 10. Manual Outdoor Air Damper:
- 11. Square-To-Round Duct Transitions (24-48 models):
- 12. Time Guard II
- 13. Low Pressure Switch Kit
577C--K Ultra Low NOx: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
9
A180216
* Part Number CPRCURB011B00 can be used on both small and large basepan units. The cross supports must be located based on whether the unit is a small basepan or a large basepan.
NOTES:
1. Roof curb must be set up for unit being installed.
2. Seal strip must be applied, as required, to unit being installed.
3. Roof curb is made of 16-gauge steel.
4. Attach ductwork to curb (flanges of duct rest on curb).
5. Insulated panels: 1-in. (25.4 mm) thick fiberglass 1 lb. density.
Accessory Dimensions
Unit Size Catalog Number
A
IN.
(mm)
B (small / common
base)
IN. (mm)*
B (large base)
IN. (mm)*
C
IN.
(mm)
D
IN.
(mm)
E
IN.
(mm)
F
IN.
(mm)
G
IN. (mm)
H
IN. (mm)
Small or
Large
CPRFCURB011B00 14 (356) 10 (254)
14 (356) 16 (406)
47.8
(1214)
32.4
(822)
2.7 (69)
30.6 (778)
46.1 (1170)
Large CPRFCURB013B00 14 (356) 14 (356)
43.9
(1116)
42.2 (1072)
RETURN
AIR
SMALL
BASE
UNIT
SUPPLY
AIR
LARGE
BASE
UNIT
UNIT PLACEMENT ON
COMMON CURB
SMALL/COMMON CURB
SMALL OR LARGE BASE UNIT
LARGE CURB