User guide

71
B.
- Set the appropriate angles from
“0/90/180/270”, according to the position
of the main unit.
Trigger +X, -X, Y,
Z
- Set the trigger levels in each axis
direction. These levels will be used to
judge over acceleration, over deceleration,
sudden turns, and excessive up-down
vibrations.
- Each trigger level can be set from 0.1G to
1.0G where 0.1G is more sensitive than
1.0G
External
Device
S2, S3 - The BRX has 3 serial ports of which S1 is
reserved for maintenance and S2 and S3
can be used to connect other devices.
- Depending on what device is connected to
the ports, select from “N/A, GPS, External
IR, EMS Alert Unit, TACHO DONGSUN,
TACHO DTE”. Leave as N/A if not used.
Baud rate -Check the specification of the device you
are connecting and select from
“4800/9600/19200/38400/115200”
- All devices by D-TEG are “9600”.