Installation guide

Chapter 2: Run the Cables Type A 18
AMF 82-70
Run both the DMO-70 (Odd Lane) and DME-70 (Even Lane) cables from the Duo Camera Module, along the
Ball Track, up the kickback, to the A&MC box located on the curtain wall, which is the common connection box for
both lanes.
Again, the start contact is wired in series to the managers control switch on AMC Pin 5 and the cycle contact
is wired in parallel across AMC pins 1 & 2 to the cycle button from the ball return. The Foul signal is also wired to the
AMC box across AMC pins 7 & 8.
Warning: Be careful when pulling out the existing AMC connections that you do not
pull out more than the intended connector by exerting too much force.
Also, make sure that no connectors are shorting out with any others,
otherwise machine faults like continual cycling could occur.
Note: The Duo units start contacts must be connected in series (in line) not in
parallel with (across) the manager’s control switch. This is to ensure that
when the manager’s control switches are switched off the pinsetter will turn
off. Normal operation will see the Managers control switch turned on, the
pinsetter will turn on and off with the games bowled. If, however, there is
an urgent need to turn the pinsetter off it can be done quickly using the
Manager's control switches.