Safety data sheet
Page 5/11
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 13.05.2016 Revision: 13.05.2016Version number 7
Trade name:
BRUNOX® Lubri-Food® (AEROSOL)
(Contd. of page 4)
42.2.22
Keep ignition sources away - Do not smoke.
Protect against electrostatic charges.
Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50 °C,
i.e. electric lights. Do not pierce or burn, even after use.
·
7.2 Conditions for safe storage, including any incompatibilities
·
Storage:
·
Requirements to be met by storerooms and receptacles:
Store in a cool location.
Observe official regulations on storing packagings with pressurised containers.
·
Information about storage in one common storage facility:
Not required.
·
Further information about storage conditions:
Store under lock and key and out of the reach of children.
Keep container tightly sealed.
Do not seal receptacle gas tight.
Store in cool, dry conditions in well sealed receptacles.
Protect from heat and direct sunlight.
·
7.3 Specific end use(s)
No further relevant information available.
SECTION 8: Exposure controls/personal protection
·
Additional information about design of technical facilities:
No further data; see item 7.
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
CAS: 124-38-9 carbon dioxide
WEL (Great Britain) Short-term value: 27400 mg/m³, 15000 ppm
Long-term value: 9150 mg/m³, 5000 ppm
NES (Australia) Short-term value: 54000 mg/m³, 30000 ppm
Long-term value: 9000 *22500 mg/m³, 5000 *12500 ppm
*in coal mines
WES (New Zealand) Short-term value: 54000 mg/m³, 30000 ppm
Long-term value: 9000 mg/m³, 5000 ppm
·
Additional information:
The lists valid during the making were used as basis.
·
8.2 Exposure controls
·
Personal protective equipment:
·
General protective and hygienic measures:
Wash hands before breaks and at the end of work.
Do not inhale gases / fumes / aerosols.
·
Respiratory protection:
Filter A/P2
Filter AX
·
Protection of hands:
The glove material has to be impermeable and resistant to the product/ the substance/ the
preparation.
(Contd. on page 6)
GB