Safety data sheet

Page 5/9
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 07.08.2013 Revision: 07.08.2013Version number 4
Trade name:
BRUNOX(R) Turbo-Spray(R) offene Ware
(Contd. of page 4)
37.1.2
*
SECTION 7: Handling and storage
·
7.1 Precautions for safe handling
Use only in well ventilated areas.
Prevent formation of aerosols.
Keep receptacles tightly sealed.
Open and handle receptacle with care.
·
Information about fire - and explosion protection:
Keep ignition sources away - Do not smoke.
Do not spray onto a naked flame or any incandescent material.
Protect against electrostatic charges.
Use explosion-proof apparatus / fittings and spark-proof tools.
·
7.2 Conditions for safe storage, including any incompatibilities
·
Storage:
·
Requirements to be met by storerooms and receptacles:
Store only in the original receptacle.
·
Information about storage in one common storage facility:
Store away from foodstuffs.
Store away from oxidizing agents.
·
Further information about storage conditions:
Store receptacle in a well ventilated area.
Store under lock and key and out of the reach of children.
·
7.3 Specific end use(s)
No further relevant information available.
*
SECTION 8: Exposure controls/personal protection
·
Additional information about design of technical facilities:
No further data; see item 7.
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
123-95-5 butyl stearate
WES (New Zealand) Long-term value: 10* mg/m³
*inhalable dust: no asbestos, <1% free silica
·
Additional information:
The lists valid during the making were used as basis.
·
8.2 Exposure controls
·
Personal protective equipment:
·
General protective and hygienic measures:
Avoid contact with the eyes and skin.
Keep away from foodstuffs, beverages and feed.
Wash hands before breaks and at the end of work.
Do not inhale gases / fumes / aerosols.
·
Respiratory protection:
Use suitable respiratory protective device in case of insufficient ventilation.
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer
exposure use self-contained respiratory protective device.
Filter A/P2
Filter AX
(Contd. on page 6)