ELECTRICAL
If the charger is subject to a power line surge,
the AC input fuse may blow. Refer to the illus-
tration to the left for fuse location.
To replace fuse:
1. Turn OFF the battery charger power switch.
2. Remove power cord from wall outlet.
3. Twist the fuseholder cap and pull out to
remove the fuse.
4. Replace with the same size and type: BUSS
#GSL 2, 5 x 20mm.
Battery charger LED’s
Battery Charger Fuse Replacement
fuse
charging
power
on
ready
power switch
RED YELLOW GREEN STATUS
ON OFF OFF charger not connected to
battery (AC power ON, no
battery connected)
ON (<5 sec.) ON (<5 sec.) ON (<5 sec.) battery disconnect situa-
tion detected (AC power
ON, battery disconnect);
5-second delay until
yellow and green LED’s
completely off
ON ON OFF
charger at maximum
voltage (constant voltage)/
delivering maximum
current (constant current)
ON ON ON batteries fully charged
ON BLINK OFF low voltage indication
ON OFF FAST BLINK battery defective or
heavily sulfated
ON BLINK ON
partially open circuit; bad
contact or battery sulfation