UNIT DOES NOT
SHUT OFF WHEN IT
HITS THE BUMPER
AT THE END OF THE
RAIL
UNIT WILL NOT
OPERATE WITH
CALL / SEND
REMOTE
UNIT OPERATES
ERRATICALLY OR
INTERMITTENTLY
WITH A RIDER
USING THE
ARMREST-MOUNTED
CONTROL SWITCH
UNIT WILL NOT
OPERATE UNLESS
THE SEAT IS
POSITIONED SO THAT
IT FACES THE OPEN
SIDE OF THE STAIRS
• Check swivel seat safety switch.
• Check that the footrest safety tray is not dragging on
the stair nosing or hitting debris on the stairs.
If necessary, reposition the stair rail
mounting brackets to correct the problem.
• Check the rail for debris that may contact safety
switches (footrest and carriage panels).
• This is correct lift operation.
• A safety switch in the seat swivel prevents the unit
from operating with the seat "out of position".
• Check batteries in remote call/send unit.
• Aim transmiter at the carriage
• Transmitters must be `learned' to receiver.
• Connections were not made correctly when changing
unit from left-side to right-side installation.
Consult wiring diagram in installation manual.
• Verify correct operation of limit switch in carriage
assembly.
• Wipe down rail.
• Apply a small amount of grease to the
gear rack only
ROUGH OR
CHATTERING RIDE
TROUBLESHOOTING