Installation manual

27
©2008,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
SRE-1550 03-18-2008
LEARNING THE REMOTE INFRARED TRANSMITTER
(not necessary when installing unit for the rst time)
SW3 switch
9V battery
(access panel
removed)
LEARN/ERASE
button
ELECTRICAL
The operating channel of the two (2) infrared
transmitters included with the SRE-2750 is
pre-set at the Bruno factory.
Reasons for relearning transmitters:
there are multiple units in the same location;
• you have to replace transmitters.
To relearn a transmitter:
1. Turn the circuit breaker OFF.
2. Remove the CARRIAGE COVER to expose the
circuit board.
3. Locate the LEARN/ERASE button on the circuit
board (see left).
4. On one of the IR TRANSMITTERS, remove the
battery access panel.
NOTE: If the transmitter is mounted to a wall,
unscrew the (2) mounting bracket screws, turn
the transmitter over and remove the battery
access panel.
5. On the TRANSMITTER board, locate the switch
labelled "SW3" (see left).
6. Change the conguration for switches 1 and 2.
Note: There are four possible congurations:
1 up, 2 down
(default manufacturer's setting)
• 1 up, 2 up
• 1 down, 2 up
• 1 down, 2 down
7. Once you have changed the switch positions:
• turn on the CARRIAGE circuit breaker;
• wait until you hear a BEEP.