Installation Sheet
In a continuing effort to offer the best product possible we reserve the right to change, without notice, specications or materials that in our opinion will not alter the function of the product.
v.5.27.21
Ledra Brands Inc.
www.LedraBrands.com
88 Maxwell
Irvine, CA 92618
P 714.259.9959
F 714.259.9969
INSTRUCTIONS FOR USE
De-energize circuit before installation.
Use 1.5mm allen key to remove back plate assembly.
Secure back plate assembly to a J-Box (J-Box and mounting hardware
supplied by others) for use with 3-1/2" and 4" octagonal or square
recessed junction boxes with 2-3/4" mounting hole spacing. (Appropriate
device ring cover may be required and to be supplied by others.)
*For xtures with rigid stems longer than 5 inches only. Feed xture
wiring through threaded end of rigid stem and thread stem on to swivel
adapter. Slide bottom locking ring over wiring and rigid stem. Align hole at
base of rigid stem with hole on bottom locking ring and tighten set screw.
Insert wiring and rigid stem into canopy. Set top locking ring ush with top
of rigid stem, align holes, and tighten safety screw. Raise canopy to until
rigid stem is fully seated. Tighten (3) stem locking screws on mounting
ange at base of canopy.
Properly ground back plate assembly and canopy in accordance with all
local and national electrical codes.
Connect line, neutral, and ground wires to building electrical supply. If
product supports optional dimming, connect dimming leads to dimming
control system (provided by others) or isolate wires individually. Refer to
product cut sheet for input voltage requirements.
Secure canopy to back plate assembly using 1.5mm allen key and place
xture into desired position.
Energize circuit and test for proper operation
1
2
3
4
5
6
7
8
h
5 1/8"
1/2"
4 1/2"
3 1/8"
h
5 1/8"
1/2"
4 1/2"
3 1/8"
3/4"
Back Plate
Top Locking Ring
w/ Set Screw
Ground
Common
Line
Canopy Set Screw
Canopy Mounting Flange
w/ Set Screws (3)
Canopy
Rigid Stem
Bottom Locking Ring
w/ Set Screw
Flexible Cable
Fixture
h
5 1/8"
1/2"
4 1/2"
3 1/8"
h
5 1/8"
1/2"
4 1/2"
3 1/8"
3/4"
Back Plate
Top Locking Ring
w/ Set Screw
Ground
Common
Line
Canopy Set Screw
Canopy Mounting Flange
w/ Set Screws (3)
Canopy
Rigid Stem
Bottom Locking Ring
w/ Set Screw
Flexible Cable
Fixture
FIELD CUT RIGID STEM
De-energize circuit before removing xture.
Remove xture from back plate using 1.5mm allen key. Remove top
locking ring. Use 1.5mm allen key to loosen set screw.
Use 2.5mm allen key to loosen (3) three stem locking set screws on
canopy mounting ange to separate rigid stem from canopy.
Loosen set screw on bottom locking ring and unscrew rigid stem to
separate from xture.
Field cut only after removed from canopy and wiring has been removed
from stem. Cut the stem to desired length and deburr the inside edge.
Drill 1/8 inch hole into top of stem. Hole must be drilled 1/8 inch from the
cut end for the safety set screw. Remove any sharp edges.
Feed xture wiring through threaded side of rigid stem. Thread stem into
swivel adapter and slide bottom locking ring into position. Align with hole
on rigid stem and tighten bottom locking ring set screw.
Feed rigid stem through canopy, insert top locking ring into position,
align hole, and tighten set screw. Raise canopy until top locking ring is
fully seated on canopy. Tighten (3) three stem locking screws on canopy
mounting ange.
Properly ground back plate assembly and canopy in accordance with all
local and national electrical codes.
Connect line, neutral, and ground wires to building electrical supply. If
product supports optional dimming, connect dimming leads to dimming
control system (provided by others) or isolate wires individually. Refer to
product cut sheet for input voltage requirements.
Secure canopy to back plate assembly using 1.5mm allen key and place
xture into desired position.
Energize circuit and test for proper operation.