Install Instructions
REMOVAL
Reverse Removal Std. Removal
4. Tighten the capscrews against the face until the screw force releases the product from the
bushing.
5. Remove the bushing and product from the shaft using appropriate means.
Shaft Size Range (IN)
Lower Shaft
Size Limit
(IN)
Shaft Size Range (MM)
Lower Shaft
Size Limit
(MM)
Through Above Through
- 1 1/2 -0.003 - 38.1 -0.076
1 1/2 2 1/2 -0.004 38.1 63.5 -0.102
2 1/2 4 -0.005 63.5 101.6 -0.127
4 6 -0.006 101.6 152.4 -0.152
6 8 -0.007 152.4 203.2 -0.178
8 9 -0.008 203.2 228.6 -0.203
9 - -0.009 228.6 - -0.229
Table 1: Shaft Size Limits for Q-D
Bushings
Note: Upper limit is + 0 whether units are inches or millimeters.
Have questions? Contact Application Engineering at 1-800-626-2093.
Bushing
SAE Grade 5.1 or
5 Cap Screw
Cap Screw Torque
Set Screw
Size
Set Screw Torque
No. Size (In-Lbs) (Ft-Lbs) (N -M) (In-Lbs) (Ft-Lbs) (N -M)
JA 3 #10 -24NC 60 5 6.8 — — — —
SH-SDS-SD 3 1/4 -20NC 108 9 12.2 1/4 -20NC 87 7.25 9.8
SK 3 5/16 -18NC 180 15 20.3 1/4 -20NC 87 7.25 9.8
SF 3 3/8 -16NC 360 30 40.7 5/16 -18NC 165 13.8 18.6
E 3 1/2 -13NC 720 60 81.4 3/8 -16NC 290 24.2 32.8
F 3 9/16 -12NC 900 75 101.7 3/8 -16NC 290 24.2 32.8
J 3 5/8 -11NC 1620 135 183.1 3/8 -16NC 290 24.2 32.8
M 4 3/4 -10NC 2700 225 305.1 3/8 -16NC 290 24.2 32.8
N 4 7/8 -9NC 3600 300 406.8 1/2 -13NC 620 51.7 70.1
P 4 1 -8NC 5400 450 610.2 1/2 -13NC 620 51.7 70.1
Table 2: Tightening Torques
(N-M) = Newton Meters
Browning, Emerson, Emerson Industrial Automation and Q-D are trademarks of
Emerson Electric Co. or one of its affiliated companies.
©1998, 1999, 2000, 2009, 2010 Emerson Power Transmission, All Rights Reserved.
MCIM10015 • F20-23 • Printed in USA