Owner's Manual

Programmer
119
Chapter 3 Programming with Command Function
Resizing
Command to be used
M
8
8 8
Resizing a pattern in the X and Y directions
F
Used to input magnification in the X direction.
Values 90 to 110 % are available for resizing.
M
Used to input magnification in the Y direction.
Values 90 to 110 % are available for resizing.
This function is available only when the needle is at the home position.
The center point (reference point) of resizing is as follows.
X coordinate : Center of the outer shape of the data
Y coordinate : Uppermost position of the data
All the settings of attributes become invalid if the pattern is resized without changing the
stitch length. Set the attributes after resizing the pattern.
1. Make sure that the needle is at the home position.
Press
R
if the needle is not at the home position.
2. Input
M
8
8 8
.
3. Input the magnification in 3 digits in the X direction, then press
F
.
Magnification values of 0 - 400 are available for input.
4. Input the magnification in 3 digits in the Y direction, then press
M
.
Magnification values of 0 - 400 are available for input.
5. Input the stitch length in 3 digits, then press
L
.
If the value is "000", the stitch count remains unchanged. The stitch length increases or decreases.
Displays the number of the magnification input.
Displays the number of the command input.
Displays the number of the magnification input.