Owner's Manual
49
BAS-364E, 366E, 370E, 375E
Chapter 10 DIP SWITCH
Chapter 10 DIP SWITCH
Note
When changing DIP switch, the power must be off.
1. Panel DIP switch functions
SW No.
A-1
A-2
A-3
A-4
A-5
A-6
A-7
A-8
When ON
Presser foot rises when presser lift switch is pressed, and does not rise automatically after
sewing is complete.
Selecting work clamp operation
-
-
For split timing only, presser foot is not raised automatically after sewing is complete.
-
Single pedal specifications using mobile foot switch. Work clamp drops when foot switch is
depressed, and sewing starts when foot switch is released.
Thread trimming sensor operation is enabled.
SW No.
B-1
B-2
B-3
B-4
B-5
B-6
B-7
B-8
When ON
Independent split mode is activated.
Split data is ignored (continuous split mode).
Thread is not trimmed after an emergency stop.
Needle cooler operates.
Thread breakage sensor sensitivity is reduced.
-
-
Feeding speed is increased.
■ DIP switch B (on side of operation panel, at the bottom)
■ DIP switch A (on side of operation panel, at the top)