Owner's Manual
11
BAS-364E, 366E, 370E, 375E
Chapter 3 INSTALLATION
14. Adjusting the air pressure
1. Air pressure should be 0.5 MPa.
The air pressure can be adjusted by pulling up and
turning the control knob w on the integrator q.
After adjustment is complete, push the control knob w
downward to lock it.
2. If water stands in the bottle of the integrator q, turn
the drain cock e in the direction indicated by an arrow
to drain the water.
Note
Open the air cock r slowly.
w
r
q
e