Owner's Manual
9. Standard adjutsments
41
BAS-343E
9-14. Checking the input voltage
1. Turn on the power switch.
2. Press the menu switch q until the X-SCALE indicator w illuminates.
3. While pressing the TEST switch e, press the R/W switch r.
4. If the input voltage is normal, the input voltage conditions will be shown in the display as indicated at right.
200-V specifications
220-V specifications
230-V specifications
100-V, 380-V, 400-V and
415-V specifications
090 ∼ 110
100 ∼ 120
105 ∼ 125
100 ∼ 120
“100” is displayed when the input voltage is 200 V.
“110” is displayed when the input voltage is
100 V (for 100-V specs.), 380 V (for 380-V specs.)
or 415 V (for 415-V specs.).
5. Press the TEST switch e once more to return the display to the normal condition.
9-15.Clearing all memory settings
• If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have
been made by means of the memory switch, for instance. In such cases, carry out the following procedure to
clear the memory, and also check the DIP switch settings.
■ While pressing the R/W switch, turn on the power. This will clear all of the memory setting.
スプリット NO.
SPLIT NO.
q
横倍率
X
-
SCALE
w
テストテスト
TESTTEST
e\
読/書
R / W
r
読/書
R / W