Owner's Manual
8. Maintenance and inspection
30
BAS-343E
3. If using the liquid cooling tank q, fill it with silicon oil
(100 cs).
8-3. Draining the oil
1. Remove and empty the waste oil container q when-
ever it is full.
2. After emptying the waste oil container q, screw it back
into its original position.
8-4. Cleaning the control box air inlet port
Use a vacuum cleaner to clean the filter in the air inlet
port w of the control box q at least once a month.
* If the machine is used while the air inlet port is blocked,
the inside of the control box will overheat.
When this happens, the overheating error code ("E-
d") will be displayed and you will not be able to oper-
ate the sewing machine.
4. If oil is to be mixed with the air in the needle cooler,
remove the black cap and fill the oiler w with silicone
oil.