Service manual
CHAPTER 7 MAINTENANCE MODE
7-20
3.12 CCD Scanner Area Setting (Maintenance mode 55)
< Function >
The machine sets the CCD scanner area and stores it into the EEPROM.
< Operating Procedure >
(1) Press the 5 key twice in the initial stage of the maintenance mode. The "SCANNER
AREA SET” will appear on the LCD.
(2) When setting of the scanner area is completed, a 4-digit number will appear on the
LCD. (e.g., 4723?)
* If you press the Stop button at this point, the machine will return to the maintenance
initial stage of the maintenance mode.
Based on this 4-digit number and referring to the input data specified in the table, input
its corresponding 5-digit data value (input data). (e.g., 4723? 47247)
(3) Save the magnification compensation setting value in the EEPROM, and then return to
the initial stage of the maintenance mode.
< Input Data for Magnification Compensation after Performing ZL2FB Maintenance 55 >
Maintenance 55 Required Input Data Input data
1 4610 4619 46156
2 4620 4629 46257
3 4630 4639 46358
4 4640 4649 46459
5 4650 4659 46550
6 4660 4669 46651
7 4670 4679 46752
8 4680 4689 46853
9 4690 4699 46954
10 4700 4709 47056
11 4710 4719 47157
12 4720 4729 47247
13 4730 4739 47359
14 4740 4749 47450
15 4750 4759 47551
16 4760 4769 47652
17 4770 4779 47753
18 4780 4789 47854
19 4790 4799 47955
20 4800 4809 48057
21 4810 4819 48158
22 4820 4829 48259
23 4830 4839 48350