l Touch the “Test” key to perform test cutting.
Position the test cutting pattern so that it does not overlap the pattern for your project.
The movement of the carriage differs from when using a cutting mat.
m Check the results of test cutting, and then, if it is acceptable, touch the “Start” key. When cutting is finished, remove the auto
blade holder (black).
There are uncut pieces as a joint part to prevent the material from moving or peeling off during paper piecing.
If the material could not be cut cleanly, other than the joint part, increase the cutting pressure.
If the test cut result is not appropriate, refer to “Changing the Perforation Length” on page 12 and change the “Perforation Length” setting.
n Remove the cap from the paper piercing tool holder. Select the paper piercing tool according to the size of hole to be
punched, and then remove the protective cap from the tip of the tool. Align on the paper piercing tool with on the paper
piercing tool holder, and then insert the tool into the tool holder. After installing the holder cap, insert the holder into the
carriage.
Be careful not to point the needle tip toward your hand.
Before inserting the holder into the carriage, check if the tool moves up and down in the holder. If the tool moves, remove the cap, and then
attach it again.
o Select “Pierce” in the preview screen.
A preview of the dot data appears.
p Touch the “Test” key to place the test paper piercing pattern.
The test pattern for paper piercing will be arranged at the same position as the test cutting pattern from step l on page 11.
Touch to move the test pattern for paper piecing to a different position.
The test pattern for paper piercing can also be moved by dragging it in the screen.