ESC i U P Specify parity setting
[ASCII] ESC i U P n
[Decimal] 27 105 85 80 n
[Hexadecimal] 1B 69 55 50 n
[Parameters] 0n2
[Description]
As an RS-232C communication setting, the parity is specified as listed below.
If n=0 None
If n=1 ODD
If n=2 EVEN
The setting is applied the next time that the machine is turned on.
ESC i U C Specify busy control
[ASCII] ESC i U C n
[Decimal] 27 105 85 67 n
[Hexadecimal] 1B 69 55 43 n
[Parameters] 0n1
[Description]
As an RS-232C communication setting, the busy control is specified as listed below.
If n=0 Hardware (DTR)
If n=1 X-ON/X-OFF
The setting is applied the next time that the machine is turned on.