Owner's Manual
9. CLEANING
BAS-300G-484, BAS-300G-484 SF
53
9-3. Draining the oil
1. Remove and empty the waste oil tank (1) whenever it is
full.
2. After emptying the waste oil tank (1), screw it back into
its original position.
9-4. Checking the regulator
1. If water collects in the bottle of the regulator (1), close
the air cock (2), and then turn the drain cock (3) in the
direction of the arrow to drain the water.
2. After draining the water, tighten the drain cock (3).
3. Open the air cock (2).
9-5. Cleaning the eye guard
Wipe the eye guard clean with a soft cloth.
NOTE:
Do not use solvents such as kerosene or thinner to clean
the eye guard.
9-6. Checking the needle
Always check that the tip of the needle is not broken and
also that the needle is not bent before starting sewing.
9-7. Lubrication
Lubricate the sewing machine while referring to "3-15. Lubrication".
2550Q
2208B
4679M
Open
Close
4678M