Owner's Manual

3. INSTALLATION
BAS-300G-484, BAS-300G-484 SF
10
3-7. Installing the pneumatic unit
1. Install the pneumatic unit underneath
the work table.
(1) Solenoid valve assembly
(2) Washers [2 pcs.]
(3) Wood screws [2 pcs.]
(4) Rubber hose
NOTE:
Make sure that the pneumatic unit
does not touch the control box or the
work table leg.
2. Disconnect the connector (5) of the
valve harness.
3. Connect the connector (6) of the
thread wiper switch to the connector
(5).
4. Connect each of the air tubes (7) to the valves so that all of the numbers match respectively. (Connect the air tube marked with a
T to valve 3.)
The air tubes (7) marked with an A connect to the front valve connections (A), and those marked with B connect to the rear
connections (B).
5. Open the air cock (8).
Valve nos.
A
fte
r
installing the pneumatic unit,
adjust the air pressure. (Refer to
"10-17. Adjusting the air pressure".)
4644M
4645M