Owner's Manual

5. USING THE OPERATION PANEL (BASIC OPERATIONS)
29
BAS-300G-484, BAS-300G-484 SF
5-6. Checking the sewing pattern
Use test feed mode to check the needle movement with only the feed mechanism operating.
Check that the needle hole does not come out from the frame of the work clamp.
1
TEST indicator illuminates
Press the TEST key.
2
COUNTER indicator illuminates
Select the program number to be checked, and then set the X-scale and
the Y-scale.
The program number will flash.
Depress the work clamp switch (1) to lower the work clamp, and then
depress the start switch (2).
The work clamp will move to the sewing start position, and then the
program number will stop flashing and illuminate steadily.
The number of stitches will appear in the menu display.
Starting continuous test feed mode
Depress the work clamp switch (1) to lower the work clamp, and then
depress and release the start switch (2).
The work clamp will start moving continuously one stitch at a time.
[Fast-forward test mode]
If the work clamp switch (1) is depressed while the work clamp is moving,
the feeding speed can be increased while the work clamp switch (1) is
depressed.
TEST indicator illuminates
If you press the
key, the feed mechanism will move
forward one stitch at a time, and if you press the
key, the feed mechanism will move backward one
stitch at a time. (The feed will move quicker if you
keep the key pressed down.)
TEST indicator switches off
If you would like sewing to start while test feeding is in
progress, press the TEST key to switch off the TEST
indicator.
When the start switch (2) is depressed, sewing will
start.
3
4
If test feeding continues to the final stitch,
it will then stop.
TEST indicator switches off
Press the TEST key.
4443Q
4957Q 4014M
4014M
4014M