Service manual
2-26
Confidential
■ Error code 10 to 12, 16 to 18
These errors do not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
Error, which cannot be specified, occurs.
■ Error code 19
The drum unit reached the end of life. (The printing is stopped.)
---
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Replace Drum
Open the Front Cover, replace the Drum Unit. Refer to the User's
Guide for instructions.
<User Check>
• Replace a new drum unit. Reset the drum counter.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.