Service manual

3-80
Confidential
9.19 Fuser Unit
(1) Release the harness of the fuser unit from the guides of the main frame R ASSY.
(2) Disconnect the connector of the low voltage power supply PCB ASSY while pushing the
hook of the connector of the fuser unit.
Fig. 3-65
(3) Put the connector of the fuser unit through the hole of the main frame R ASSY.
Fig. 3-66
Guide
Guides
Connector
(low voltage power
supply PCB ASSY)
Main frame R ASSY
Connector
(low voltage power
supply PCB ASSY)
Connector (fuser unit)
Connector (fuser unit)
Hook
Connector (fuser unit)
Hole