Service manual
3-63
Confidential
9.12 Pull Arm L / Pull Arm R / Pull Arm Spring
(1) Disconnect the two connectors and the flat cable from the main PCB ASSY.
Fig. 3-47
Harness routing: Refer to “17. Panel unit”, “18. Document scanner unit”.
Main PCB ASSY
CN26CN5 CN4
FB FG harness
Main PCB ASSY
Flat cable
Connector
(Polygon motor harness ASSY)
Flat cable
Connector
(Panel harness
ASSY)