Service manual

3-57
Confidential
9.10.13
ADF motor
(1) Remove the ferrite core from the guide, and disconnect the connector of the ADF motor
harness ASSY from the ADF motor.
(2) Remove the taptite cup S M3x6 SR screw, and remove the FG harness.
Fig. 3-41
Taptite cup S M3x6 SR
Ferrite core
ADF motor
Guide
FG harness
Connector
(ADF motor harness ASSY)
2
1a
1b