Service manual

2-83
Confidential
Poor fixing
Completely blank
User Check
Check the machine's environment. High temperature and high
humidity or low temperature and low humidity conditions can cause
this problem.
Clean the corona wire of drum unit.
Replace the drum unit with a new one.
Replace the toner cartridge with a new one.
Return the green envelope levers to the home position. (Refer to
Fig. 2-8.)
Remove the elastic band from the drum unit.
Step Cause Remedy
1 Fuser unit failure Replace the fuser unit.
2 Laser unit failure Replace the laser unit.
3
Low voltage power supply PCB
ASSY failure
Replace the low voltage power supply PCB
ASSY.
4 Main PCB failure Replace the main PCB ASSY.
User Check
Check the machine's environment. High temperature and high
humidity or low temperature and low humidity conditions can cause
this problem.
Clean the corona wire of drum unit.
Replace the drum unit with a new one.
Replace the toner cartridge with a new one.
Remove the elastic band from the drum unit.
Step Cause Remedy
1
Dirt on the electrodes of the drum
unit and the machine body
Clean the electrodes of the drum unit and
machine body. (Refer to Fig. 2-11, Fig. 2-
12.)
2
Scanner harness of the laser unit
connection failure
Reconnect the scanner harness of the
laser unit.
3
Laser unit not assembled correctly Assemble the laser unit correctly and
secure the screw.
4 Laser unit failure Replace the laser unit.
5
High voltage power supply PCB
ASSY failure
Replace the high voltage power supply
PCB ASSY.
6 Main PCB failure Re-assemble the main PCB ASSY.