No. Setting items Setting range Unit Default
08 Knife X position compensation -0.5
∼
0.5mm 0.1 0.0
09 Knife Y position compensation -0.7
∼
0.7mm 0.1 0.0
10 Start tying stitches 0
∼
2 stitches 1 0
11 End tying stitches 0
∼
2 stitches 1 0
12 X alignment -1
∼
610
13 Y alignment -1
∼
610
14
θ1 alignment
-3
∼
310
15
θ2 alignment
-3
∼
310
16 Eyelet machine speed (Note 2) -600
∼
0rpm 100 0
(Note 2) Eyelet speed will be decided according to the speed which is set to the parameter 00